Reliability of the VmaxST Portable Metabolic Measurement System

Overview
Publisher Thieme
Specialty Orthopedics
Date 2008 Jul 25
PMID 18651368
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study was to evaluate the reliability of the VmaxST portable metabolic measurement system. Forty-five healthy adults (age = 25.7 +/- 5.9 yr; height = 171.8 +/- 9.1 cm; weight = 69.6 +/- 12.8 kg; VO2peak) = 40.7 ml/kg/min; percent fat = 21.7 +/- 11.0) performed two separate and identical exercise routines on different days consisting of treadmill walking at 2.0 mph (53.6 m/min), 3.0 mph (80.5 m/min), and 4.0 mph (107.3 m/min) and running at 6.0 mph (160.9 m/min). VE and gas exchange were measured continuously breath-to-breath. A random effects model on log-transformed data yielded coefficients of variation (CV) and intraclass correlation coefficients (ICC) for VO2 and VE of 5.2 - 7.6 %, and 0.77 - 0.92, respectively, for all walking and running trials. For VCO2, CVs were higher (10 - 12 %) and ICCs lower (0.70 - 0.81). Ordinary least squares regression between the individual difference scores and the individual mean scores for VE, VO2 and VCO2, respectively, indicated no systematic bias (all p > 0.05). Bland-Altman analysis also illustrated no systematic bias between repeated measurements. The VmaxST provides reliable measurements of VO2 and VE during walking and running eliciting VE and VO2 at least up to approximately 56 and 2.2 l/min, respectively. The system appears to be less reliable for measuring VCO2.

Citing Articles

Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment.

Montoye A, Vondrasek J, Hancock 2nd J Int J Exerc Sci. 2020; 13(4):1382-1401.

PMID: 33042375 PMC: 7523887. DOI: 10.70252/THJT1177.


Open-circuit respirometry: a historical review of portable gas analysis systems.

Macfarlane D Eur J Appl Physiol. 2017; 117(12):2369-2386.

PMID: 29043499 DOI: 10.1007/s00421-017-3716-8.


Test-retest reliability and minimum detectable change using the K4b2: oxygen consumption, gait efficiency, and heart rate for healthy adults during submaximal walking.

Darter B, Rodriguez K, Wilken J Res Q Exerc Sport. 2013; 84(2):223-31.

PMID: 23930548 PMC: 4023251. DOI: 10.1080/02701367.2013.784720.


Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Shephard R, Aoyagi Y Eur J Appl Physiol. 2011; 112(8):2785-815.

PMID: 22160180 DOI: 10.1007/s00421-011-2268-6.


Repeatability of aerobic capacity measurements in Parkinson disease.

Katzel L, Sorkin J, Macko R, Smith B, Ivey F, Shulman L Med Sci Sports Exerc. 2011; 43(12):2381-7.

PMID: 21606869 PMC: 3701959. DOI: 10.1249/MSS.0b013e31822432d4.


References
1.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

2.
Crouter S, Antczak A, Hudak J, DellaValle D, Haas J . Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems. Eur J Appl Physiol. 2006; 98(2):139-51. DOI: 10.1007/s00421-006-0255-0. View

3.
Brehm M, Harlaar J, Groepenhof H . Validation of the portable VmaxST system for oxygen-uptake measurement. Gait Posture. 2004; 20(1):67-73. DOI: 10.1016/S0966-6362(03)00097-3. View

4.
Martin P, Rothstein D, Larish D . Effects of age and physical activity status on the speed-aerobic demand relationship of walking. J Appl Physiol (1985). 1992; 73(1):200-6. DOI: 10.1152/jappl.1992.73.1.200. View

5.
King G, McLaughlin J, Howley E, Bassett Jr D, Ainsworth B . Validation of Aerosport KB1-C portable metabolic system. Int J Sports Med. 1999; 20(5):304-8. DOI: 10.1055/s-2007-971135. View