» Articles » PMID: 33042375

Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment

Overview
Journal Int J Exerc Sci
Date 2020 Oct 12
PMID 33042375
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

This study assessed validity and reliability of the VO Master Pro portable metabolic analyzer for assessment of oxygen consumption (VO) and minute ventilation (VE). In Protocol 1, eight male participants (height: 182.6 ± 5.8 cm, weight: 79.6 ± 8.3 kg, age: 41.0 ± 12.3 years) with previous competitive cycling experience completed an hour-long stationary cycling protocol twice, progressing from 100-300 Watts every 10 minutes while wearing the VO Master and a criterion measure (Parvomedics) for five minutes each, at each stage. In Protocol 2, 16 recreationally active male participants (height: 168.2 ± 8.4 cm, weight: 76.5 ± 13.3 kg, age: 23.0 ± 9.4 years) completed three incremental, maximal stationary cycling tests wearing one of three analyzers for each test (VO Master version 1.1.1, VO Master version 1.2.1, Parvomedics). For Protocol 1 and convergent validity, the VO Master had mean absolute differences from the Parvomedics of <0.3 L/min for absolute VO and <5 L/min for VE overall and at each exercise stage. Mean absolute percent differences (MAPD) for VO and VE were <9% overall and <12% at each stage. Test-retest reliability of the VO Master (MAPD: 8.9-10.9%) was somewhat poorer than the Parvomedics (MAPD: 5.3-7.6%). For Protocol 2, validity was similar for both VO Master models (MAPD ~12% overall) compared to the Parvomedics for VO and VE. The VO Master had an acceptable validity and test-retest reliability for most intensities tested and may be an appealing option for field-based VO and VE analysis.

Citing Articles

(Re)assessment of the COSMED Quark CPET and VO2Master Pro Systems for Measuring Pulmonary Gas Exchange and Ventilation.

Thiessen J, Guluzade N, Faricier R, Keir D Scand J Med Sci Sports. 2025; 35(2):e70019.

PMID: 39888076 PMC: 11780302. DOI: 10.1111/sms.70019.


Validation of a tri-axial accelerometer for measuring physical activity in patients with subacute stroke.

Kimura Y, Suzuki Y, Kubo H, Yoshida K, Ota T, Shimizu N Front Rehabil Sci. 2025; 5():1496515.

PMID: 39850918 PMC: 11754406. DOI: 10.3389/fresc.2024.1496515.


Differences in Cardiorespiratory Responses with Three Set-Paced Submaximal Endurance Tests in Community-Dwelling Older Adults.

Dias K, Rhyne R, Callahan D, Durbin K, Kasten A, Heitzman J Int J Exerc Sci. 2024; 17(4):1026-1037.

PMID: 39253053 PMC: 11382772. DOI: 10.70252/PYAW2914.


Feasibility of a Novel Augmented 6-Minute Incremental Step Test: A Simplified Cardiorespiratory Fitness Assessment Tool.

Molinger J, Kittipibul V, Gray J, Rao V, Barth S, Swavely A JACC Adv. 2024; 3(8):101079.

PMID: 39099774 PMC: 11294698. DOI: 10.1016/j.jacadv.2024.101079.


Assessing the Accuracy of Smartwatch-Based Estimation of Maximum Oxygen Uptake Using the Apple Watch Series 7: Validation Study.

Caserman P, Yum S, Gobel S, Reif A, Matura S JMIR Biomed Eng. 2024; 9:e59459.

PMID: 39083800 PMC: 11325102. DOI: 10.2196/59459.


References
1.
Thomas S, Buckon C, Schwartz M, Russman B, Sussman M, Aiona M . Variability and minimum detectable change for walking energy efficiency variables in children with cerebral palsy. Dev Med Child Neurol. 2009; 51(8):615-21. DOI: 10.1111/j.1469-8749.2008.03214.x. View

2.
Vogler A, Rice A, Gore C . Validity and reliability of the Cortex MetaMax3B portable metabolic system. J Sports Sci. 2010; 28(7):733-42. DOI: 10.1080/02640410903582776. View

3.
Rubenbauer J, Johannsen D, Baier S, Litchfield R, Flakoll P . The use of a handheld calorimetry unit to estimate energy expenditure during different physiological conditions. JPEN J Parenter Enteral Nutr. 2006; 30(3):246-50. DOI: 10.1177/0148607106030003246. View

4.
Duffield R, Dawson B, Pinnington H, Wong P . Accuracy and reliability of a Cosmed K4b2 portable gas analysis system. J Sci Med Sport. 2004; 7(1):11-22. DOI: 10.1016/s1440-2440(04)80039-2. View

5.
Meyer T, Davison R, Kindermann W . Ambulatory gas exchange measurements--current status and future options. Int J Sports Med. 2005; 26 Suppl 1:S19-27. DOI: 10.1055/s-2004-830507. View