» Articles » PMID: 18634935

Fatigue Resistance of Engine-driven Rotary Nickel-titanium Instruments Produced by New Manufacturing Methods

Overview
Journal J Endod
Publisher Elsevier
Specialty Dentistry
Date 2008 Jul 19
PMID 18634935
Citations 85
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of the present study was to investigate whether cyclic fatigue resistance is increased for nickel-titanium instruments manufactured by using new processes. This was evaluated by comparing instruments produced by using the twisted method (TF; SybronEndo, Orange, CA) and those using the M-wire alloy (GTX; Dentsply Tulsa-Dental Specialties, Tulsa, OK) with instruments produced by a traditional NiTi grinding process (K3, SybronEndo). Tests were performed with a specific cyclic fatigue device that evaluated cycles to failure of rotary instruments inside curved artificial canals. Results indicated that size 06-25 TF instruments showed a significant increase (p < 0.05) in the mean number of cycles to failure when compared with size 06-25 K3 files. Size 06-20 K3 instruments showed no significant increase (p > 0.05) in the mean number of cycles to failure when compared with size 06-20 GT series X instruments. The new manufacturing process produced nickel-titanium rotary files (TF) significantly more resistant to fatigue than instruments produced with the traditional NiTi grinding process. Instruments produced with M-wire (GTX) were not found to be more resistant to fatigue than instruments produced with the traditional NiTi grinding process.

Citing Articles

Paediatric Rotary Files and Dentinal Crack Formation in Primary Teeth: A Systematic Review.

Sulaiman S, A V, Ramar K, Ponraj S, Varghese A Cureus. 2025; 17(1):e77033.

PMID: 39917135 PMC: 11798756. DOI: 10.7759/cureus.77033.


Comparison of Cyclic Fatigue Resistance of ProTaper Next and TruNatomy Endodontic Rotary Files.

Ramteke P, Prajapati M, Vashisth D, Aga N, Mohanty R, Chougule P J Pharm Bioallied Sci. 2024; 16(Suppl 3):S2126-S2128.

PMID: 39346307 PMC: 11426750. DOI: 10.4103/jpbs.jpbs_107_24.


Comparison of cyclic fatigue resistance of four pediatric rotary file systems at body temperature: an in vitro study.

Surme K, Akman H, Ozkan H, Er K BMC Oral Health. 2024; 24(1):992.

PMID: 39180032 PMC: 11344432. DOI: 10.1186/s12903-024-04739-z.


The effect of canal curvature on cyclic fatigue resistance of rotary instruments using different irrigation materials ( study).

Alsunboli M, Ihsan S, Sabah D F1000Res. 2024; 12:449.

PMID: 38721249 PMC: 11078266. DOI: 10.12688/f1000research.130249.2.


Surface roughness and cyclic fatigue resistance of a novel shaping system: An in-vitro study.

Ozel B, Barut G, Baser Can E PLoS One. 2024; 19(5):e0302551.

PMID: 38696475 PMC: 11065293. DOI: 10.1371/journal.pone.0302551.