Breath Isoprene--aspects of Normal Physiology Related to Age, Gender and Cholesterol Profile As Determined in a Proton Transfer Reaction Mass Spectrometry Study

Abstract

Background: This study was performed to clarify variations in breath isoprene concentrations with age, gender, body mass index (BMI) and total serum cholesterol. Our cohort consisted of 205 adult volunteers of different smoking background without health complaints. Total cholesterol in blood serum was measured in 79 of these volunteers.

Methods: Mixed expiratory exhaled breath was sampled using Tedlar bags. Concentrations of isoprene were then determined using proton transfer reaction-mass spectrometry.

Results: Isoprene concentrations ranged from 5.8 to 274.9 ppb, with an overall geometric mean (GM) of 99.3 ppb. There was no statistically significant difference in mean isoprene in breath between males and females (GM 105.4 and 95.5 ppb, respectively). Ageing led to a decrease in concentration in men, with an estimated slope of the regression line for log-transformed isoprene concentrations of -0.0049, but did not influence isoprene levels in women. We did not observe any significant correlation between isoprene breath content and cholesterol level in blood, even after adjusting for the possible influence of age. Similarly, no correlation was found between isoprene levels and BMI.

Conclusions: Isoprene concentrations in exhaled breath showed gender-specific correlations with respect to age. Further investigations are necessary to clarify the relation between isoprene concentrations in exhaled breath and cholesterol levels and synthesis rates in blood.

Citing Articles

Noninvasive Total Cholesterol Level Measurement Using an E-Nose System and Machine Learning on Exhaled Breath Samples.

Paleczek A, Grochala J, Grochala D, Slowik J, Pihut M, Loster J ACS Sens. 2024; 9(12):6630-6637.

PMID: 39577863 PMC: 11686513. DOI: 10.1021/acssensors.4c02198.


Improved isoprene detection performance of Si-doped WO films deposited by sputtering and post-annealing.

Lin P, Qin Y, Qi X, Huang L RSC Adv. 2024; 14(19):13618-13627.

PMID: 38665489 PMC: 11043919. DOI: 10.1039/d4ra00184b.


Origin of breath isoprene in humans is revealed via multi-omic investigations.

Sukul P, Richter A, Junghanss C, Schubert J, Miekisch W Commun Biol. 2023; 6(1):999.

PMID: 37777700 PMC: 10542801. DOI: 10.1038/s42003-023-05384-y.


Identification of Volatile Markers of Colorectal Cancer from Tumor Tissues Using Volatilomic Approach.

Mezmale L, Leja M, lescinska A, Pcolkins A, Kononova E, Bogdanova I Molecules. 2023; 28(16).

PMID: 37630241 PMC: 10459111. DOI: 10.3390/molecules28165990.


Identification of Key Volatile Organic Compounds Released by Gastric Tissues as Potential Non-Invasive Biomarkers for Gastric Cancer.

Mochalski P, Leja M, Slefarska-Wolak D, Mezmale L, Patsko V, Ager C Diagnostics (Basel). 2023; 13(3).

PMID: 36766440 PMC: 9914709. DOI: 10.3390/diagnostics13030335.