» Articles » PMID: 18594994

Differences in Precision in Bone Mineral Density Measured by SXA and DXA: the NOREPOS Study

Overview
Journal Eur J Epidemiol
Specialty Public Health
Date 2008 Jul 3
PMID 18594994
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

The aims were to compare the precision (reliability) in single X-ray (SXA) and dual X-ray (DXA) absorptiometry, and to compare smallest detectable difference (SDD). An additional aim was to examine determinants for precision in bone mineral density (BMD). BMD was measured by SXA (DTX-100, Osteometer) in the forearm and by DXA (Lunar Expert) in the forearm and in the hip. Two measurements were performed at each site/method, and 195 of 207 participants had complete datasets. Participants were aged 47-49 and 71-74 years. The precision was estimated by Root Mean Square Standard Deviation (RMS SD) with 95% Confidence Interval (95%CI) and the corresponding coefficients of variation (CV%). Determinants (age, gender, BMD) were analysed by multiple linear regression with log (SD) and log (CV) as dependent variables. RMS SD tended to be largest in older women and in those with low BMD. RMS SD for SXA and DXA forearm was 4.6 (4.2-5.1) and 6.8 (6.1-7.4) and the corresponding CVs 1.0% and 1.4%. RMS SD for DXA hip was 11.0 (9.9-12.0) with CV 1.2%. To detect a 3% change in BMD one would need two repeated measurements by DXA in the distal forearm at each of two consultations, but only one measurement by SXA in the distal forearm and also only one measurement by DXA in the hip. Precision differed by type of densitometer affecting the number of repeated measurements needed to detect a given BMD difference.

Citing Articles

Comparison of trabecular bone microarchitecture between older males with and without a running habit: A cross-sectional study.

Zhang C, Wang S, Meng F, Shu D, Huang H, Zhang Y J Exerc Sci Fit. 2025; 23(2):83-89.

PMID: 39898366 PMC: 11786814. DOI: 10.1016/j.jesf.2025.01.002.


Updated practice guideline for dual-energy X-ray absorptiometry (DXA).

Slart R, Punda M, Ali D, Bazzocchi A, Bock O, Camacho P Eur J Nucl Med Mol Imaging. 2024; 52(2):539-563.

PMID: 39316095 PMC: 11732917. DOI: 10.1007/s00259-024-06912-6.


Bone mineral density and risk of cardiovascular disease in men and women: the HUNT study.

Bhatta L, Cepelis A, Vikjord S, Malmo V, Laugsand L, Dalen H Eur J Epidemiol. 2021; 36(11):1169-1177.

PMID: 34515906 PMC: 8629874. DOI: 10.1007/s10654-021-00803-y.


Physical capability, physical activity, and their association with femoral bone mineral density in adults aged 40 years and older: The Tromsø study 2015-2016.

Hauger A, Holvik K, Bergland A, Stahle A, Emaus N, Morseth B Osteoporos Int. 2021; 32(10):2083-2094.

PMID: 33864108 PMC: 8510966. DOI: 10.1007/s00198-021-05949-9.


A Digital Model to Simulate Effects of Bone Architecture Variations on Texture at Spatial Resolutions of CT, HR-pQCT, and μCT Scanners.

Lowitz T, Museyko O, Bousson V, Kalender W, Laredo J, Engelke K J Med Eng. 2016; 2014:946574.

PMID: 27006936 PMC: 4782631. DOI: 10.1155/2014/946574.


References
1.
Meyer H, Berntsen G, Sogaard A, Langhammer A, Schei B, Fonnebo V . Higher bone mineral density in rural compared with urban dwellers: the NOREPOS study. Am J Epidemiol. 2004; 160(11):1039-46. DOI: 10.1093/aje/kwh337. View

2.
Alver K, Meyer H, Falch J, Sogaard A . Bone mineral density in ethnic Norwegians and Pakistani immigrants living in Oslo--The Oslo Health Study. Osteoporos Int. 2004; 16(6):623-30. DOI: 10.1007/s00198-004-1722-2. View

3.
Sievanen H, Backstrom M, Kuusela A, Ikonen R, Maki M . Dual energy x-ray absorptiometry of the forearm in preterm and term infants: evaluation of the methodology. Pediatr Res. 1999; 45(1):100-5. DOI: 10.1203/00006450-199901000-00017. View

4.
Baim S, Wilson C, Lewiecki E, Luckey M, Downs Jr R, Lentle B . Precision assessment and radiation safety for dual-energy X-ray absorptiometry: position paper of the International Society for Clinical Densitometry. J Clin Densitom. 2005; 8(4):371-8. DOI: 10.1385/jcd:8:4:371. View

5.
Faulkner K, McClung M . Quality control of DXA instruments in multicenter trials. Osteoporos Int. 1995; 5(4):218-27. DOI: 10.1007/BF01774010. View