» Articles » PMID: 18584097

Silane-dextran Chemistry on Lateral Flow Polymer Chips for Immunoassays

Overview
Journal Lab Chip
Specialties Biotechnology
Chemistry
Date 2008 Jun 28
PMID 18584097
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

The prognosis for patients suffering from cardiovascular and many other diseases can be substantially improved if diagnosed at an early stage. High performance diagnostic testing using disposable microfluidic chips can provide a platform for realizing this vision. Amic AB (Uppsala, Sweden) has developed a new microfluidic test chip for sandwich immunoassays fabricated by injection molding of the cycloolefin-copolymer Zeonor. A highly ordered array of micropillars within the fluidic chip distributes the sample solution by capillary action. Since wetting of the pillar array surface is the only driving force for liquid distribution precise control of the surface chemistry is crucial. In this work we demonstrate a novel protocol for surface hydrophilization and antibody immobilization on cycloolefin-copolymer test chips, based on direct silanisation of the thermoplastic substrate. Dextran is subsequently covalently coupled to amino groups, thus providing a coating with a low contact angle suitable for antibody immobilization. The contact angle of dextran coated chips is stable for at least two months, which enables production of large batches that can be stored for extended periods of time. We demonstrate the utility of the presented platform and surface chemistry in a C-reactive protein assay with a detection limit of 2.6 ng ml(-1), a dynamic range of 10(2) and a coefficient of variance of 15%.

Citing Articles

Range of effectiveness of hydraulic diameter model as an analytical solution for rectangular microchannels.

Kobayashi K, Sakamoto K Heliyon. 2025; 11(1):e41498.

PMID: 39850432 PMC: 11755038. DOI: 10.1016/j.heliyon.2024.e41498.


Trends in ready-to-use portable electrochemical sensing devices for healthcare diagnosis.

Sajeevan A, Sukumaran R, Panicker L, Kotagiri Y Mikrochim Acta. 2025; 192(2):80.

PMID: 39808331 DOI: 10.1007/s00604-024-06916-x.


Lateral Flow Immunoassays for Detecting Viral Infectious Antigens and Antibodies.

Alhabbab R Micromachines (Basel). 2022; 13(11).

PMID: 36363922 PMC: 9694796. DOI: 10.3390/mi13111901.


Immobilization of Active Antibodies at Polymer Melt Surfaces during Injection Molding.

Hobaek T, Pranov H, Larsen N Polymers (Basel). 2022; 14(20).

PMID: 36298004 PMC: 9606872. DOI: 10.3390/polym14204426.


Application of Microfluidic Chips in the Detection of Airborne Microorganisms.

Wang J, Yang L, Wang H, Wang L Micromachines (Basel). 2022; 13(10).