» Articles » PMID: 18574588

The Annoyance of Snoring

Overview
Date 2008 Jun 25
PMID 18574588
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Is the annoyance of snoring a reliable tool for the measurement of snoring or does it depend more on the sensitivity of the listener? During an automatized hearing experiment, 550 representative snoring sequences, recorded during polysomnography, were randomly presented to ten examiners for the evaluation of their annoyance (0-100). The mean annoyance score for each snoring sound and the covariance parameters for rater and snoring sounds (restricted maximum likelihood method) were calculated. The average annoyance rating of all snoring sequences was 63.9+/-23.0, the most acceptable snoring sequence rating was 49.2+/-28.0, the most annoying rating was 77.7+/-16.4. The covariance parameters were estimated as 28.7% for the rater and 22.3% for the snoring sound. Our results show that the listeners' noise sensitivity is at least equally relevant for the snoring annoyance as the snoring sound itself.

Citing Articles

How to objectively measure snoring: a systematic review.

Kim S, Cho S, Rhee C, Kim J Sleep Breath. 2023; 28(1):1-9.

PMID: 37421520 DOI: 10.1007/s11325-023-02865-6.


The Annoying Nature of Snoring Sounds Is Not Only about Intensity: A Pilot Study on Exposed Test Subjects.

Huang Z, Aarab G, Ravesloot M, de Vries N, Hilgevoord A, Lobbezoo F J Clin Med. 2023; 12(7).

PMID: 37048713 PMC: 10095263. DOI: 10.3390/jcm12072630.


Acoustic Analysis of Snoring in the Diagnosis of Obstructive Sleep Apnea Syndrome: A Call for More Rigorous Studies.

Jin H, Lee L, Song L, Li Y, Peng J, Zhong N J Clin Sleep Med. 2015; 11(7):765-71.

PMID: 25766705 PMC: 4481061. DOI: 10.5664/jcsm.4856.


The efficacy of a chinstrap in treating sleep disordered breathing and snoring.

Bhat S, Gushway-Henry N, Polos P, DeBari V, Riar S, Gupta D J Clin Sleep Med. 2014; 10(8):887-92.

PMID: 25126035 PMC: 4106943. DOI: 10.5664/jcsm.3962.


Are subjective assessments of snoring sounds reliable?.

Rohrmeier C, Fischer R, Merz A, Ettl T, Herzog M, Kuehnel T Eur Arch Otorhinolaryngol. 2014; 272(1):233-40.

PMID: 25085635 DOI: 10.1007/s00405-014-3211-3.


References
1.
McNicholas W, Bonsigore M, Bonsignore M . Sleep apnoea as an independent risk factor for cardiovascular disease: current evidence, basic mechanisms and research priorities. Eur Respir J. 2007; 29(1):156-78. DOI: 10.1183/09031936.00027406. View

2.
Young T, Palta M, Dempsey J, Skatrud J, Weber S, Badr S . The occurrence of sleep-disordered breathing among middle-aged adults. N Engl J Med. 1993; 328(17):1230-5. DOI: 10.1056/NEJM199304293281704. View

3.
Terris D, Coker J, Thomas A, Chavoya M . Preliminary findings from a prospective, randomized trial of two palatal operations for sleep-disordered breathing. Otolaryngol Head Neck Surg. 2002; 127(4):315-23. DOI: 10.1067/mhn.2002.128345. View

4.
Fujita S . UPPP for sleep apnea and snoring. Ear Nose Throat J. 1984; 63(5):227-35. View

5.
Shrout P, Fleiss J . Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979; 86(2):420-8. DOI: 10.1037//0033-2909.86.2.420. View