» Articles » PMID: 18567650

Torsional Ultrasound Modality for Hard Nucleus Phacoemulsification Cataract Extraction

Overview
Journal Br J Ophthalmol
Specialty Ophthalmology
Date 2008 Jun 24
PMID 18567650
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: To evaluate the efficacy and safety of phacoemulsification using torsional modality with different parameter settings for hard nucleus cataract extraction.

Design: A prospective, randomised clinical study.

Methods: A clinical practice study conducted at the Cataract Service, Zhongshan Ophthalmic Center, Sun-Yat-Sen University, and Guangzhou. One eye each from 198 consecutive patients with cataract density grade IV according to the Emery-Little system classification system, requiring phacoemulsification and intraocular lens implantation, was included. Eyes were randomly assigned to the Linear Torsional combined with Ultrasound power group (Linear Tor+US group, n = 66), 100% Fixed Torsional group (Fixed Tor group, n = 65) and conventional Ultrasound burst group (US group, n = 67). All surgeries were performed by a single experienced surgeon and outcomes evaluated by another surgeon masked to treatment. Intraoperative parameters were Ultrasound Time (UST), Cumulative Dissipated Energy (CDE) and surgical complications. Patients were examined on post-op days 1, 7 and 30. Postoperative outcomes were final best corrected visual acuity (BCVA), average central and incisional corneal thickness and central endothelial cell counts.

Results: The mean UST was lower in the Fixed Tor group than in the US group and in the Lin US+Tor group (p<or=0.0001). The mean CDE was lower in the Lin Tor+US group and in the Fixed Tor group than in the US group (p<or=0.0001). Comparing with the two Tor group, the US group had a lower average BCVA on post-op 1, 7 (p<or=0.0001) and 30 (p>0.01), greater average central corneal and incisional thickness on days 1, 7 (p<or=0.0001) and 30 (p>0.01), and higher average corneal endothelial cell losses on day 7 and 30 days (p<or=0.0001).

Conclusions: Torsional combined with ultrasound power or high fixed torsional amplitude can yield more effective hard nucleus phacoemulsification than conventional ultrasound modality.

Citing Articles

Air bubble guide for adequacy of ophthalmic viscosurgical device during phacoemulsification.

Nath M, Odayappan A, Tripathy K, Nachiappan S Indian J Ophthalmol. 2024; 72(6):916-918.

PMID: 38767550 PMC: 11232843. DOI: 10.4103/IJO.IJO_2998_23.


Laminin α4 overexpression in the anterior lens capsule may contribute to the senescence of human lens epithelial cells in age-related cataract.

Yan Y, Yu H, Sun L, Liu H, Wang C, Wei X Aging (Albany NY). 2019; 11(9):2699-2723.

PMID: 31076560 PMC: 6535067. DOI: 10.18632/aging.101943.


Comparison of surgical parameters using different lens fragmentation patterns in eyes undergoing laser-assisted cataract surgery.

Uy H, Chan P, Gil-Cazorla R, Shah S Int Ophthalmol. 2019; 39(11):2459-2465.

PMID: 30830545 DOI: 10.1007/s10792-019-01087-8.


Comparison of clinical outcomes between cystotome-assisted prechop phacoemulsification surgery and conventional phacoemulsification surgery for hard nucleus cataracts: A CONSORT-compliant article.

Li X, He Y, Su T, Tian Y, Wang Y, Xia X Medicine (Baltimore). 2018; 97(46):e13124.

PMID: 30431580 PMC: 6257572. DOI: 10.1097/MD.0000000000013124.


Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification.

Modis L, Szalai E, Flasko Z, Nemeth G Rom J Ophthalmol. 2018; 60(2):109-115.

PMID: 29450332 PMC: 5711360.


References
1.
Miyata K, Nagamoto T, Maruoka S, Tanabe T, Nakahara M, Amano S . Efficacy and safety of the soft-shell technique in cases with a hard lens nucleus. J Cataract Refract Surg. 2002; 28(9):1546-50. DOI: 10.1016/s0886-3350(02)01323-8. View

2.
Gimbel H, Pereira C . Advances in phacoemulsification equipment. Curr Opin Ophthalmol. 2002; 13(1):30-2. DOI: 10.1097/00055735-200202000-00007. View

3.
Kim E, Cristol S, Geroski D, McCarey B, Edelhauser H . Corneal endothelial damage by air bubbles during phacoemulsification. Arch Ophthalmol. 1997; 115(1):81-8. DOI: 10.1001/archopht.1997.01100150083014. View

4.
Floyd M, Valentine J, Olson R . Fluidics and heat generation of Alcon Infiniti and Legacy, Bausch & Lomb Millennium, and advanced medical optics sovereign phacoemulsification systems. Am J Ophthalmol. 2006; 142(3):387-92. DOI: 10.1016/j.ajo.2006.04.042. View

5.
Liu Y, Jiang Y, Liu Y, Wu M . [A preliminary report on bimanual microphacoemulsification]. Zhonghua Yan Ke Za Zhi. 2004; 40(5):302-5. View