Internal Mechanical Conditions in the Soft Tissues of a Residual Limb of a Trans-tibial Amputee

Overview
Journal J Biomech
Specialty Physiology
Date 2008 May 23
PMID 18495134
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Most trans-tibial amputation (TTA) patients use a prosthesis to retain upright mobility capabilities. Unfortunately, interaction between the residual limb and the prosthetic socket causes elevated internal strains and stresses in the muscle and fat tissues in the residual limb, which may lead to deep tissue injury (DTI) and other complications. Presently, there is paucity of information on the mechanical conditions in the TTA residual limb during load-bearing. Accordingly, our aim was to characterize the mechanical conditions in the muscle flap of the residual limb of a TTA patient after donning the prosthetic socket and during load-bearing. Knowledge of internal mechanical conditions in the muscle flap can be used to identify the risk for DTI and improve the fitting of the prosthesis. We used a patient-specific modelling approach which involved an MRI scan, interface pressure measurements between the residual limb and the socket of the prosthesis and three-dimensional non-linear large-deformation finite-element (FE) modelling to quantify internal soft tissue strains and stresses in a female TTA patient during static load-bearing. Movement of the truncated tibia and fibula during load-bearing was measured by means of MRI and used as displacement boundary conditions for the FE model. Subsequently, we calculated the internal strains, strain energy density (SED) and stresses in the muscle flap under the truncated bones. Internal strains under the tibia peaked at 85%, 129% and 106% for compression, tension and shear strains, respectively. Internal strains under the fibula peaked at substantially lower values, that is, 19%, 22% and 19% for compression, tension and shear strains, respectively. Strain energy density peaked at the tibial end (104kJ/m(3)). The von Mises stresses peaked at 215kPa around the distal end of the tibia. Stresses under the fibula were at least one order of magnitude lower than the stresses under the tibia. We surmise that our present patient-specific modelling method is an important tool in understanding the etiology of DTI in the residual limbs of TTA patients.

Citing Articles

Soft tissue material properties based on human abdominal macro-indenter measurements.

Remus R, Sure C, Selkmann S, Uttich E, Bender B Front Bioeng Biotechnol. 2024; 12:1384062.

PMID: 38854855 PMC: 11157078. DOI: 10.3389/fbioe.2024.1384062.


Evaluation and Comparison of Stress in Divergent and Convergent Collar Designs of Implants With Different Bone Densities: A Finite Element Study.

Panmei G, Kumar A, Basak S, Anal S, Nongthombam R, Mall B Cureus. 2023; 15(3):e36550.

PMID: 37095819 PMC: 10121484. DOI: 10.7759/cureus.36550.


Editorial: Bionics limb prostheses: Advances in clinical and prosthetic care.

Frossard L, Conforto S, Aszmann O Front Rehabil Sci. 2022; 3:950481.

PMID: 36189016 PMC: 9397676. DOI: 10.3389/fresc.2022.950481.


Developing a control framework for self-adjusting prosthetic sockets incorporating tissue injury risk estimation and generalized predictive control.

Mbithi F, Chipperfield A, Steer J, Dickinson A Biomed Eng Lett. 2022; 12(1):59-73.

PMID: 35186360 PMC: 8825909. DOI: 10.1007/s13534-021-00211-x.


Subthreshold Vibration Influences Standing Balance but Has Unclear Impact on Somatosensation in Persons With Transtibial Amputations.

Meade Z, Likens A, Kent J, Takahashi K, Wurdeman S, Jacobsen A Front Physiol. 2022; 13:810079.

PMID: 35185618 PMC: 8847287. DOI: 10.3389/fphys.2022.810079.