Digital Chest Radiography: an Update on Modern Technology, Dose Containment and Control of Image Quality

Overview
Journal Eur Radiol
Specialty Radiology
Date 2008 Apr 24
PMID 18431577
Citations 47
Authors
Affiliations
Soon will be listed here.
Abstract

The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems.

Citing Articles

Evaluation of X-ray Beam Collimation in Adult Chest Radiography.

Aloufi K, Gameraddin M, Albdrani A, Alsani M, Alshoabi S Cureus. 2024; 16(9):e68489.

PMID: 39364522 PMC: 11448963. DOI: 10.7759/cureus.68489.


Automated Quality Control Solution for Radiographic Imaging of Lung Diseases.

Kleefeld C, Castillo Lopez J, Costa P, Fitton I, Mohamed A, Pesznyak C J Clin Med. 2024; 13(16).

PMID: 39201109 PMC: 11355187. DOI: 10.3390/jcm13164967.


Performance of artificial intelligence-based software for the automatic detection of lung lesions on chest radiographs of patients with suspected lung cancer.

Takamatsu A, Ueno M, Yoshida K, Kobayashi T, Kobayashi S, Gabata T Jpn J Radiol. 2023; 42(3):291-299.

PMID: 38032419 PMC: 10899395. DOI: 10.1007/s11604-023-01503-1.


Pulmonary abnormality screening on chest x-rays from different machine specifications: a generalized AI-based image manipulation pipeline.

Shin H, Kim T, Park J, Raj H, Jabbar M, Abebaw Z Eur Radiol Exp. 2023; 7(1):68.

PMID: 37940797 PMC: 10632317. DOI: 10.1186/s41747-023-00386-1.


The effect of breast shielding outside the field of view on breast entrance surface dose in axial X-ray examinations: a phantom study.

Hurley L, Alashban Y, Albeshan S, England A, McEntee M Diagn Interv Radiol. 2023; 29(3):555-560.

PMID: 37129301 PMC: 10679606. DOI: 10.4274/dir.2023.232126.


References
1.
Bankier A, Schaefer-Prokop C, De Maertelaer V, Tack D, Jaksch P, Klepetko W . Air trapping: comparison of standard-dose and simulated low-dose thin-section CT techniques. Radiology. 2007; 242(3):898-906. DOI: 10.1148/radiol.2423060196. View

2.
Honey I, MacKenzie A, Evans D . Investigation of optimum energies for chest imaging using film-screen and computed radiography. Br J Radiol. 2005; 78(929):422-7. DOI: 10.1259/bjr/32912696. View

3.
Sund P, Bath M, Kheddache S, Mansson L . Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography. Eur Radiol. 2003; 14(1):48-58. DOI: 10.1007/s00330-003-1971-z. View

4.
Schuncke A, Neitzel U . Retrospective patient dose analysis of a digital radiography system in routine clinical use. Radiat Prot Dosimetry. 2005; 114(1-3):131-4. DOI: 10.1093/rpd/nch535. View

5.
Uffmann M, Neitzel U, Prokop M, Kabalan N, Weber M, Herold C . Flat-panel-detector chest radiography: effect of tube voltage on image quality. Radiology. 2005; 235(2):642-50. DOI: 10.1148/radiol.2352031730. View