» Articles » PMID: 18416836

Effects of Dielectrophoresis on Growth, Viability and Immuno-reactivity of Listeria Monocytogenes

Overview
Journal J Biol Eng
Publisher Biomed Central
Date 2008 Apr 18
PMID 18416836
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Dielectrophoresis (DEP) has been regarded as a useful tool for manipulating biological cells prior to the detection of cells. Since DEP uses high AC electrical fields, it is important to examine whether these electrical fields in any way damage cells or affect their characteristics in subsequent analytical procedures. In this study, we investigated the effects of DEP manipulation on the characteristics of Listeria monocytogenes cells, including the immuno-reactivity to several Listeria-specific antibodies, the cell growth profile in liquid medium, and the cell viability on selective agar plates. It was found that a 1-h DEP treatment increased the cell immuno-reactivity to the commercial Listeria species-specific polyclonal antibodies (from KPL) by ~31.8% and to the C11E9 monoclonal antibodies by ~82.9%, whereas no significant changes were observed with either anti-InlB or anti-ActA antibodies. A 1-h DEP treatment did not cause any change in the growth profile of Listeria in the low conductive growth medium (LCGM); however, prolonged treatments (4 h or greater) caused significant delays in cell growth. The results of plating methods showed that a 4-h DEP treatment (5 MHz, 20 Vpp) reduced the viable cell numbers by 56.8-89.7 %. These results indicated that DEP manipulation may or may not affect the final detection signal in immuno-based detection depending on the type of antigen-antibody reaction involved. However, prolonged DEP treatment for manipulating bacterial cells could produce negative effects on the cell detection by growth-based methods. Careful selection of DEP operation conditions could avoid or minimize negative effects on subsequent cell detection performance.

Citing Articles

Beyond two dimensions: Exploring 3D dielectrophoresis for microparticle control using carbon electrodes.

Pilloni O, Madou M, Oropeza-Ramos L PLoS One. 2024; 19(9):e0310978.

PMID: 39325809 PMC: 11426537. DOI: 10.1371/journal.pone.0310978.


Dielectrophoresis as a tool for electrophysiological characterization of stem cells.

Giduthuri A, Theodossiou S, Schiele N, Srivastava S Biophys Rev (Melville). 2024; 1(1):011304.

PMID: 38505626 PMC: 10903368. DOI: 10.1063/5.0025056.


Comparing machine learning and deep learning regression frameworks for accurate prediction of dielectrophoretic force.

Ajala S, Jalajamony H, Nair M, Marimuthu P, Fernandez R Sci Rep. 2022; 12(1):11971.

PMID: 35831342 PMC: 9279499. DOI: 10.1038/s41598-022-16114-5.


Ten-Second Electrophysiology: Evaluation of the 3DEP Platform for high-speed, high-accuracy cell analysis.

Hoettges K, Henslee E, Torcal Serrano R, Jabr R, Abdallat R, Beale A Sci Rep. 2019; 9(1):19153.

PMID: 31844107 PMC: 6915758. DOI: 10.1038/s41598-019-55579-9.


Toward point-of-care assessment of patient response: a portable tool for rapidly assessing cancer drug efficacy using multifrequency impedance cytometry and supervised machine learning.

Ahuja K, Rather G, Lin Z, Sui J, Xie P, Le T Microsyst Nanoeng. 2019; 5:34.

PMID: 31645995 PMC: 6799891. DOI: 10.1038/s41378-019-0073-2.


References
1.
Cheng J, Sheldon E, Wu L, Heller M, OConnell J . Isolation of cultured cervical carcinoma cells mixed with peripheral blood cells on a bioelectronic chip. Anal Chem. 1998; 70(11):2321-6. DOI: 10.1021/ac971274g. View

2.
Lapizco-Encinas B, Davalos R, Simmons B, Cummings E, Fintschenko Y . An insulator-based (electrodeless) dielectrophoretic concentrator for microbes in water. J Microbiol Methods. 2005; 62(3):317-26. DOI: 10.1016/j.mimet.2005.04.027. View

3.
Gass G, Chernomordik L . Reversible large-scale deformations in the membranes of electrically-treated cells: electroinduced bleb formation. Biochim Biophys Acta. 1990; 1023(1):1-11. DOI: 10.1016/0005-2736(90)90002-6. View

4.
Verduzco-Luque C, Alp B, Stephens G, Markx G . Construction of biofilms with defined internal architecture using dielectrophoresis and flocculation. Biotechnol Bioeng. 2003; 83(1):39-44. DOI: 10.1002/bit.10646. View

5.
Yang L, Ruan C, Li Y . Detection of viable Salmonella typhimurium by impedance measurement of electrode capacitance and medium resistance. Biosens Bioelectron. 2003; 19(5):495-502. DOI: 10.1016/s0956-5663(03)00229-x. View