» Articles » PMID: 18316191

Reliability of COP-based Postural Sway Measures and Age-related Differences

Overview
Journal Gait Posture
Specialty Orthopedics
Date 2008 Mar 5
PMID 18316191
Citations 115
Authors
Affiliations
Soon will be listed here.
Abstract

The objectives of this study were to assess the within-day and between-day reliability of several center of pressure (COP)-based measures of postural sway and identify whether there were age-related differences in reliability. Thirty-two healthy individuals (16 younger and 16 older) participated. COP was recorded during quiet upright stance on 4 different days, and a variety of measures determined: mean velocity, median power frequency, RMS distance, sway area, and two fractal measures derived from Hurst rescaled range analysis (HR/S) and detrended fluctuation analysis (DFA). Intraclass correlation coefficient (ICC) and standard error of measurement (SEM) were used to quantify reliability. Mean velocity was the most reliable measure. DFA exponents had relatively better reliability than HR/S exponents. In general, within-day reliability was better than between-day. In comparison with younger participants, older participants exhibited better relative reliability (ICC) for all COP measures and comparable absolute reliability (SEM) except for mean velocity and sway area. These results may be useful in guiding the future selection and interpretation of COP-based measures.

Citing Articles

Influence of cognitive demand and auditory noise on postural dynamics.

Carey S, Balasubramaniam R Exp Brain Res. 2025; 243(2):54.

PMID: 39891705 PMC: 11787163. DOI: 10.1007/s00221-025-06998-w.


Spatial variability and directional shifts in postural control in Parkinson's disease.

Kelty-Stephen D, Kiyono K, Stergiou N, Mangalam M Clin Park Relat Disord. 2024; 10:100249.

PMID: 38803658 PMC: 11129103. DOI: 10.1016/j.prdoa.2024.100249.


Postural control in gymnasts: anisotropic fractal scaling reveals proprioceptive reintegration in vestibular perturbation.

Mangalam M, Seleznov I, Kolosova E, Popov A, Kelty-Stephen D, Kiyono K Front Netw Physiol. 2024; 4:1393171.

PMID: 38699200 PMC: 11063314. DOI: 10.3389/fnetp.2024.1393171.


Assessing Motor Variability during Squat: The Reliability of Inertial Devices in Resistance Training.

Garcia-Aguilar F, Lopez-Fernandez M, Barbado D, Moreno F, Sabido R Sensors (Basel). 2024; 24(6).

PMID: 38544213 PMC: 10974361. DOI: 10.3390/s24061951.


Effect of dynamic neuromuscular stabilization training using the inertial load of water on functional movement and postural sway in middle-aged women: a randomized controlled trial.

Kang S, Park I, Ha M BMC Womens Health. 2024; 24(1):154.

PMID: 38438927 PMC: 10910739. DOI: 10.1186/s12905-024-02972-w.