» Articles » PMID: 18236222

A Controlled Inhalation Diesel Exhaust Exposure Facility with Dynamic Feedback Control of PM Concentration

Overview
Journal Inhal Toxicol
Publisher Informa Healthcare
Specialty Toxicology
Date 2008 Feb 1
PMID 18236222
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

A facility has been assembled that provides a controlled inhalation exposure to freshly diluted and mixed diesel exhaust using a diesel engine under load and a two-stage exhaust dilution system with dynamic feedback control. The concentrations of particulate matter less than 2.5 microm in diameter (PM(2.5)), particulate carbon, and gaseous pollutants including carbon monoxide and oxides of nitrogen (NOx) have been characterized and the exposure conditions have been found to be both stable and reproducible. Control of the PM(2.5) concentration at intended levels relies on the relatively linear relationship between particle light scattering and exhaust particle mass concentration. While the exposure system does not entirely replicate diesel exhaust conditions in the atmosphere due to the relatively low ratio of nitrogen dioxide to total NOx, the fine particulate matter size distributions are quite similar to those of aged diesel exhaust. The facility enables study of the relationship between diesel exhaust and cardiovascular and respiratory health effects in human and animal models.

Citing Articles

Source Apportionment of Environmental Combustion Sources using Excitation Emission Matrix Fluorescence Spectroscopy and Machine Learning.

Rutherford J, Larson T, Gould T, Seto E, Novosselov I, Posner J Atmos Environ (1994). 2021; 259.

PMID: 34321954 PMC: 8312701. DOI: 10.1016/j.atmosenv.2021.118501.


Acute exposure to traffic-related air pollution alters antioxidant status in healthy adults.

Cosselman K, Allen J, Jansen K, Stapleton P, Trenga C, Larson T Environ Res. 2020; 191:110027.

PMID: 32810504 PMC: 8568481. DOI: 10.1016/j.envres.2020.110027.


Developing a Low-Cost Passive Method for Long-Term Average Levels of Light-Absorbing Carbon Air Pollution in Polluted Indoor Environments.

Clark L, Sreekanth V, Bekbulat B, Baum M, Yang S, Baylon P Sensors (Basel). 2020; 20(12).

PMID: 32560462 PMC: 7348734. DOI: 10.3390/s20123417.


Excitation Emission Matrix Fluorescence Spectroscopy for Combustion Generated Particulate Matter Source Identification.

Rutherford J, Dawson-Elli N, Manicone A, Korshin G, Novosselov I, Seto E Atmos Environ (1994). 2020; 220.

PMID: 32256182 PMC: 7111209. DOI: 10.1016/j.atmosenv.2019.117065.


Diesel Exhaust Induces Mitochondrial Dysfunction, Hyperlipidemia, and Liver Steatosis.

Yin F, Gupta R, Vergnes L, Driscoll W, Ricks J, Ramanathan G Arterioscler Thromb Vasc Biol. 2019; 39(9):1776-1786.

PMID: 31340670 PMC: 6703953. DOI: 10.1161/ATVBAHA.119.312736.