» Articles » PMID: 18088422

The Roman Bridge: a "double Pulley - Suture Bridges" Technique for Rotator Cuff Repair

Overview
Publisher Biomed Central
Specialties Orthopedics
Physiology
Date 2007 Dec 20
PMID 18088422
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

Background: With advances in arthroscopic surgery, many techniques have been developed to increase the tendon-bone contact area, reconstituting a more anatomic configuration of the rotator cuff footprint and providing a better environment for tendon healing.

Methods: We present an arthroscopic rotator cuff repair technique which uses suture bridges to optimize rotator cuff tendon-footprint contact area and mean pressure.

Results: Two medial row 5.5-mm Bio-Corkscrew suture anchors (Arthrex, Naples, FL), which are double-loaded with No. 2 FiberWire sutures (Arthrex, Naples, FL), are placed in the medial aspect of the footprint. Two suture limbs from a single suture are both passed through a single point in the rotator cuff. This is performed for both anchors. The medial row sutures are tied using the double pulley technique. A suture limb is retrieved from each of the medial anchors through the lateral portal, and manually tied as a six-throw surgeon's knot over a metal rod. The two free suture limbs are pulled to transport the knot over the top of the tendon bridge. Then the two free suture limbs that were used to pull the knot down are tied. The end of the sutures are cut. The same double pulley technique is repeated for the other two suture limbs from the two medial anchors, but the two free suture limbs are used to produce suture bridges over the tendon, by means of a Pushlock (Arthrex, Naples, FL), placed 1 cm distal to the lateral edge of the footprint.

Conclusion: This technique maximizes the advantages of two techniques. On the one hand, the double pulley technique provides an extremely secure fixation in the medial aspect of the footprint. On the other hand, the suture bridges allow to improve pressurized contact area and mean footprint pressure. In this way, the bony footprint in not compromised by the distal-lateral fixation, and it is thus possible to share the load between fixation points. This maximizes the strength of the repair and provides a barrier preventing penetration of synovial fluid into the healing area of tendon and bone.

Citing Articles

Exploring the Impact of Socially Assistive Robots in Rehabilitation Scenarios.

Carnevale A, Raso A, Antonacci C, Mancini L, Corradini A, Ceccaroli A Bioengineering (Basel). 2025; 12(2).

PMID: 40001723 PMC: 11851852. DOI: 10.3390/bioengineering12020204.


A pilot study for assessing NAO humanoid robot assistance in shoulder rehabilitation.

Raso A, Pulcinelli M, Schena E, Puglisi A, Pioggia G, Carnevale A J Exp Orthop. 2024; 12(1):e70122.

PMID: 39737429 PMC: 11683783. DOI: 10.1002/jeo2.70122.


The bioinductive collagen implant yields positive histological, clinical and MRI outcomes in the management of rotator cuff tears: A systematic review.

Longo U, Marino M, de Sire A, Ruiz-Iban M, DHooghe P Knee Surg Sports Traumatol Arthrosc. 2024; 33(3):1070-1090.

PMID: 39234682 PMC: 11848954. DOI: 10.1002/ksa.12429.


Immersive virtual reality for shoulder rehabilitation: evaluation of a physical therapy program executed with oculus quest 2.

Longo U, Carnevale A, Andreoli F, Mannocchi I, Bravi M, Sassi M BMC Musculoskelet Disord. 2023; 24(1):859.

PMID: 37919702 PMC: 10621204. DOI: 10.1186/s12891-023-06861-5.


Application of Machine Learning Algorithms for Prognostic Assessment in Rotator Cuff Pathologies: A Clinical Data-Based Approach.

Longo U, Di Naro C, Campisi S, Casciaro C, Bandini B, Pareek A Diagnostics (Basel). 2023; 13(18).

PMID: 37761282 PMC: 10530213. DOI: 10.3390/diagnostics13182915.


References
1.
Franceschi F, Longo U, Ruzzini L, Rizzello G, Maffulli N, Denaro V . No advantages in repairing a type II superior labrum anterior and posterior (SLAP) lesion when associated with rotator cuff repair in patients over age 50: a randomized controlled trial. Am J Sports Med. 2007; 36(2):247-53. DOI: 10.1177/0363546507308194. View

2.
Smith C, Alexander S, Hill A, Huijsmans P, Bull A, Amis A . A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair. J Bone Joint Surg Am. 2006; 88(11):2425-31. DOI: 10.2106/JBJS.E.00697. View

3.
Park M, Tibone J, ElAttrache N, Ahmad C, Jun B, Lee T . Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg. 2007; 16(4):469-76. DOI: 10.1016/j.jse.2006.09.011. View

4.
Franceschi F, Ruzzini L, Longo U, Martina F, Zobel B, Maffulli N . Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: a randomized controlled trial. Am J Sports Med. 2007; 35(8):1254-60. DOI: 10.1177/0363546507302218. View

5.
Millett P, Mazzocca A, Guanche C . Mattress double anchor footprint repair: a novel, arthroscopic rotator cuff repair technique. Arthroscopy. 2004; 20(8):875-9. DOI: 10.1016/j.arthro.2004.07.015. View