» Articles » PMID: 18081870

Immediately Loaded Titanium Implant with a Tissue-stabilizing/maintaining Design ('beyond Platform Switch') Retrieved from Man After 4 Weeks: a Histological and Histomorphometrical Evaluation. A Case Report

Overview
Specialty Dentistry
Date 2007 Dec 18
PMID 18081870
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Background: After implant insertion and loading, crestal bone usually undergoes remodeling and resorption. If the horizontal relationship between the outer edge of the implant and a smaller-diameter component ('platform switching') is altered, there seems to be reduced crestal bone loss. Immediate loading allows immediate restoration of esthetics and function, reduces morbidity, and facilitates functional rehabilitation.

Materials And Methods: Three Morse cone connection implants were inserted in the right posterior mandible in a 29-year-old partially edentulous patient. The platform of the implant was inserted 2 mm below the level of the alveolar crest. After a 1-month loading period, the most distal mandibular implant was retrieved with a trephine bur for psychological reasons.

Results: At low-power magnification, it was possible to see that bone was present 2 mm above the level of the implant shoulder. No resorption of the coronal bone was present. No infrabony pockets were present. At the level of the shoulder of the implant, it was possible to observe the presence of dense connective tissue with only a few scattered inflammatory cells. Newly formed bone was found in direct contact with the implant surface. The bone-implant contact percentage was 65.3+/-4.8%.

Conclusions: Abutments smaller than the diameter of the implant body (platform switching) in combination with an absence of micromovement and microgap may protect the peri-implant soft and mineralized tissues, explaining the observed absence of bone resorption. Immediate loading did not interfere with bone formation and did not have adverse effects on osseointegration.

Citing Articles

Biomechanical Stress Analysis of Platform Switch Implants of Varying Diameters on Different Densities of Bone.

Mukherjee S, Rodrigues S, M M, Shetty T, Pai U, Saldanha S Int J Dent. 2022; 2022:5972259.

PMID: 35251181 PMC: 8894074. DOI: 10.1155/2022/5972259.


Behavior of Soft Tissue around Platform-Switched Implants and Non-Platform-Switched Implants: A Comparative Three-Year Clinical Study.

Farronato D, Manfredini M, Farronato M, Pasini P, Orsina A, Lops D J Clin Med. 2021; 10(13).

PMID: 34209354 PMC: 8269426. DOI: 10.3390/jcm10132955.


The influence of the implant-abutment complex on marginal bone and peri-implant conditions: A retrospective study.

Ergin Tokgoz S, Bilhan H J Adv Prosthodont. 2021; 13(1):46-54.

PMID: 33747394 PMC: 7943754. DOI: 10.4047/jap.2021.13.1.46.


A Narrative Review of the Histological and Histomorphometrical Evaluation of the Peri-Implant Bone in Loaded and Unloaded Dental Implants. A 30-Year Experience (1988-2018).

Tumedei M, Piattelli A, Degidi M, Mangano C, Iezzi G Int J Environ Res Public Health. 2020; 17(6).

PMID: 32245226 PMC: 7143607. DOI: 10.3390/ijerph17062088.


Ratio between Height and Thickness of the Buccal Tissues: A Pilot Study on 32 Single Implants.

Farronato D, Manfredini M, Mangano F, Goffredo G, Colombo M, Pasini P Dent J (Basel). 2019; 7(2).

PMID: 30987026 PMC: 6631890. DOI: 10.3390/dj7020040.