» Articles » PMID: 18072476

A Rigidity Penalty Term for Nonrigid Registration

Overview
Journal Med Phys
Specialty Biophysics
Date 2007 Dec 13
PMID 18072476
Citations 41
Authors
Affiliations
Soon will be listed here.
Abstract

Medical images that are to be registered for clinical application often contain both structures that deform and ones that remain rigid. Nonrigid registration algorithms that do not model properties of different tissue types may result in deformations of rigid structures. In this article a local rigidity penalty term is proposed which is included in the registration function in order to penalize the deformation of rigid objects. This term can be used for any representation of the deformation field capable of modelling locally rigid transformations. By using a B-spline representation of the deformation field, a fast algorithm can be devised. The proposed method is compared with an unconstrained nonrigid registration algorithm. It is evaluated on clinical three-dimensional CT follow-up data of the thorax and on two-dimensional DSA image sequences. The results show that nonrigid registration using the proposed rigidity penalty term is capable of nonrigidly aligning images, while keeping user-defined structures locally rigid.

Citing Articles

Three-dimensional characterization of sex differences in abdominal aortic aneurysm progression via vascular deformation mapping.

Braet D, Baker T, Delbono L, Spahlinger G, Graham N, Arora A Sci Rep. 2024; 14(1):24215.

PMID: 39414930 PMC: 11484807. DOI: 10.1038/s41598-024-75334-z.


MUsculo-Skeleton-Aware (MUSA) deep learning for anatomically guided head-and-neck CT deformable registration.

Liu H, McKenzie E, Xu D, Xu Q, Chin R, Ruan D Med Image Anal. 2024; 99:103351.

PMID: 39388843 PMC: 11817760. DOI: 10.1016/j.media.2024.103351.


Generalized div-curl based regularization for physically constrained deformable image registration.

Tzitzimpasis P, Ries M, Raaymakers B, Zachiu C Sci Rep. 2024; 14(1):15002.

PMID: 38951683 PMC: 11217375. DOI: 10.1038/s41598-024-65896-3.


MAIRNet: weakly supervised anatomy-aware multimodal articulated image registration network.

Gao X, Zhong W, Wang R, Heimann A, Tannast M, Zheng G Int J Comput Assist Radiol Surg. 2024; 19(3):507-517.

PMID: 38236477 DOI: 10.1007/s11548-023-03056-0.


SPECT and CT misregistration reduction in [Tc]Tc-MAA SPECT/CT for precision liver radioembolization treatment planning.

Lu Z, Chen G, Jiang H, Sun J, Lin K, Mok G Eur J Nucl Med Mol Imaging. 2023; 50(8):2319-2330.

PMID: 36877236 DOI: 10.1007/s00259-023-06149-9.