Pharmacokinetics of High-dose Nebulized Amikacin in Mechanically Ventilated Healthy Subjects

Overview
Specialty Critical Care
Date 2007 Nov 30
PMID 18046534
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Nebulized amikacin may be an attractive option for the treatment of lung infections. Low systemic absorption may permit the use of high doses, leading to high lung concentrations without systemic toxicity. We evaluated the pharmacokinetics and safety of an optimized high-dose amikacin nebulization technique.

Design: in vitro and in vivo pharmacokinetic study.

Patients And Participants: Six healthy volunteers (age 21-30 years, weight 49-68 kg).

Interventions: The Aeroneb Pro nebulizer with an Idehaler vertical spacer was evaluated in a bench study. Amikacin was administered intravenously (15[Symbol: see text]mg/kg) and nebulized (40, 50, and 60[Symbol: see text]mg/kg) during noninvasive pressure-support ventilation through a mouthpiece.

Measurements And Results: Median (interquartile range) in vitro inhaled fraction was 31% (30-32) and inhalable output was 681 mg/h (630-743). Serum concentrations after nebulization were less than or equal to those after infusion. The area under the serum concentration curve was significantly higher after infusion (138 mg h(-1)l(-1), 122-143) than after nebulization (49 mg h(-1)l(-1), 39-55, at 40 mg/kg; 63, 53-67 at 50; 66, 50-71, at 60). Peak serum concentration was also higher after infusion: 48 mg/l (45-49) after infusion compared to 8.2 (5.6-8.7), 9.2 (7.6-10.2), and 9.2 (5.2-10.3), respectively. Mean absorption times after nebulization were 2 h 24 min (2,07-2,45), 2 h 21 min (2,07-2,35), and 2 h 5 min (2,00-2,25), respectively. No side effect was observed.

Conclusions: Nebulization of up to 60 mg/kg amikacin appears to be safe in healthy subjects and associated with lower serum concentrations than a 15 mg/kg infusion.

Citing Articles

Aerosolized antibiotics in the treatment of hospital-acquired pneumonia/ventilator-associated pneumonia.

Jung Y, Kim E, Choi Y Korean J Intern Med. 2021; 37(1):1-12.

PMID: 34666432 PMC: 8747925. DOI: 10.3904/kjim.2021.277.


Inhaled amikacin versus placebo to prevent ventilator-associated pneumonia: the AMIKINHAL double-blind multicentre randomised controlled trial protocol.

Tavernier E, Barbier F, Meziani F, Quenot J, Herbrecht J, Landais M BMJ Open. 2021; 11(9):e048591.

PMID: 34521664 PMC: 8442072. DOI: 10.1136/bmjopen-2020-048591.


Inhaled antibiotics during mechanical ventilation-why it will work.

Desgrouas M, Ehrmann S Ann Transl Med. 2021; 9(7):598.

PMID: 33987296 PMC: 8105850. DOI: 10.21037/atm-20-3686.


SPECT-CT Comparison of Lung Deposition using a System combining a Vibrating-mesh Nebulizer with a Valved Holding Chamber and a Conventional Jet Nebulizer: a Randomized Cross-over Study.

Dugernier J, Hesse M, Vanbever R, Depoortere V, Roeseler J, Michotte J Pharm Res. 2016; 34(2):290-300.

PMID: 27822851 DOI: 10.1007/s11095-016-2061-7.


Inhaled Antibiotics for Gram-Negative Respiratory Infections.

Wenzler E, Fraidenburg D, Scardina T, Danziger L Clin Microbiol Rev. 2016; 29(3):581-632.

PMID: 27226088 PMC: 4978611. DOI: 10.1128/CMR.00101-15.


References
1.
Rello J, Paiva J, Baraibar J, Barcenilla F, Bodi M, Castander D . International Conference for the Development of Consensus on the Diagnosis and Treatment of Ventilator-associated Pneumonia. Chest. 2001; 120(3):955-70. DOI: 10.1378/chest.120.3.955. View

2.
Harvey C, ODoherty M, Page C, Thomas S, Nunan T, Treacher D . Effect of a spacer on pulmonary aerosol deposition from a jet nebuliser during mechanical ventilation. Thorax. 1995; 50(1):50-3. PMC: 473707. DOI: 10.1136/thx.50.1.50. View

3.
Dubus J, Vecellio L, De Monte M, Fink J, Grimbert D, Montharu J . Aerosol deposition in neonatal ventilation. Pediatr Res. 2005; 58(1):10-4. DOI: 10.1203/01.PDR.0000156244.84422.55. View

4.
Moss R . Long-term benefits of inhaled tobramycin in adolescent patients with cystic fibrosis. Chest. 2002; 121(1):55-63. DOI: 10.1378/chest.121.1.55. View

5.
Elman M, Goldstein I, Marquette C, Wallet F, Lenaour G, Rouby J . Influence of lung aeration on pulmonary concentrations of nebulized and intravenous amikacin in ventilated piglets with severe bronchopneumonia. Anesthesiology. 2002; 97(1):199-206. DOI: 10.1097/00000542-200207000-00028. View