» Articles » PMID: 18044960

Fully Automated Four-column Capillary LC-MS System for Maximizing Throughput in Proteomic Analyses

Overview
Journal Anal Chem
Specialty Chemistry
Date 2007 Nov 30
PMID 18044960
Citations 94
Authors
Affiliations
Soon will be listed here.
Abstract

We describe a four-column, high-pressure capillary liquid chromatography (LC) system for robust, high-throughput liquid chromatography-mass spectrometry (LC-MS(/MS)) analyses. This system performs multiple LC separations in parallel, but staggers each of them such that the data-rich region of each separation is sampled sequentially. By allowing nearly continuous data acquisition, this design maximizes the use of the mass spectrometer. Each analytical column is connected to a corresponding ESI emitter in order to avoid the use of postcolumn switching and associated dead volume issues. Encoding translation stages are employed to sequentially position the emitters at the MS inlet. The high reproducibility of this system is demonstrated using consecutive analyses of global tryptic digest of the microbe Shewanella oneidensis.

Citing Articles

Robust collection and processing for label-free single voxel proteomics.

Kitata R, Velickovic M, Xu Z, Zhao R, Scholten D, Chu R Nat Commun. 2025; 16(1):547.

PMID: 39805815 PMC: 11730317. DOI: 10.1038/s41467-024-54643-x.


Multicolumn Nanoflow Liquid Chromatography with Accelerated Offline Gradient Generation for Robust and Sensitive Single-Cell Proteome Profiling.

Xie X, Truong T, Huang S, Johnston S, Hovanski S, Robinson A Anal Chem. 2024; 96(26):10534-10542.

PMID: 38915247 PMC: 11482043. DOI: 10.1021/acs.analchem.4c00878.


A compendium of multi-omics data illuminating host responses to lethal human virus infections.

Eisfeld A, Anderson L, Fan S, Walters K, Halfmann P, Westhoff Smith D Sci Data. 2024; 11(1):328.

PMID: 38565538 PMC: 10987564. DOI: 10.1038/s41597-024-03124-3.


Deciphering ApoE Genotype-Driven Proteomic and Lipidomic Alterations in Alzheimer's Disease Across Distinct Brain Regions.

Odenkirk M, Zheng X, Kyle J, Stratton K, Nicora C, Bloodsworth K J Proteome Res. 2024; 23(8):2970-2985.

PMID: 38236019 PMC: 11255128. DOI: 10.1021/acs.jproteome.3c00604.


Multidimensional Separations in Top-Down Proteomics.

Guo Y, Cupp-Sutton K, Zhao Z, Anjum S, Wu S Anal Sci Adv. 2024; 4(5-6):181-203.

PMID: 38188188 PMC: 10769458. DOI: 10.1002/ansa.202300016.


References
1.
Kelly R, Page J, Luo Q, Moore R, Orton D, Tang K . Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry. Anal Chem. 2006; 78(22):7796-801. PMC: 1769309. DOI: 10.1021/ac061133r. View

2.
Deng Y, Zeng H, Unger S, Wu J . Multiple-sprayer tandem mass spectrometry with parallel high flow extraction and parallel separation for high-throughput quantitation in biological fluids. Rapid Commun Mass Spectrom. 2001; 15(17):1634-40. DOI: 10.1002/rcm.422. View

3.
Shen Y, Strittmatter E, Zhang R, Metz T, Moore R, Li F . Making broad proteome protein measurements in 1-5 min using high-speed RPLC separations and high-accuracy mass measurements. Anal Chem. 2005; 77(23):7763-73. DOI: 10.1021/ac051257o. View

4.
Tiller P, Romanyshyn L, Neue U . Fast LC/MS in the analysis of small molecules. Anal Bioanal Chem. 2003; 377(5):788-802. DOI: 10.1007/s00216-003-2146-0. View

5.
Yang L, Mann T, Little D, Wu N, Clement R, Rudewicz P . Evaluation of a four-channel multiplexed electrospray triple quadrupole mass spectrometer for the simultaneous validation of LC/MS/MS methods in four different preclinical matrixes. Anal Chem. 2001; 73(8):1740-7. DOI: 10.1021/ac0012694. View