» Articles » PMID: 17982738

[Simulation of Blood Flow Within the Abdominal Aorta. Computational Fluid Dynamics in Abdominal Aortic Aneurysms Before and After Interventions]

Overview
Journal Radiologe
Specialty Radiology
Date 2007 Nov 6
PMID 17982738
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

The goal of numeric analysis of aortic blood flow is to evaluate the mechanisms leading to an aortic aneurysm with regard to the risk of a rupture and to describe the effect of interventional therapy. Numeric analysis is based on virtual models of vascular structures and the physical characteristics of the vessel wall, of blood as fluidum, and the blood flow. Using this information, numeric analysis solves the appropriate equations. The results can be displayed quantitatively and qualitatively. The results of numeric flow simulation show that in abdominal aortic aneurysms the wall pressure, which is of vital importance for the risk of rupture, depends on several factors, one being the location of the intraluminal thrombus. In models of aneurysms after stent grafting, numeric analysis can be used to evaluate factors leading to stent migration. Although numeric analysis of aortic blood flow still has several limitations, recent studies have shown that this method has the potential for improved estimation of the rupture risk of aortic aneurysms in the near future.

Citing Articles

Modelling blood flow in patients with heart valve disease using deep learning: A computationally efficient method to expand diagnostic capabilities in clinical routine.

Yevtushenko P, Goubergrits L, Franke B, Kuehne T, Schafstedde M Front Cardiovasc Med. 2023; 10:1136935.

PMID: 36937926 PMC: 10020717. DOI: 10.3389/fcvm.2023.1136935.

References
1.
Fillinger M, Raghavan M, Marra S, Cronenwett J, Kennedy F . In vivo analysis of mechanical wall stress and abdominal aortic aneurysm rupture risk. J Vasc Surg. 2002; 36(3):589-97. DOI: 10.1067/mva.2002.125478. View

2.
Juchems M, Pless D, Fleiter T, Gabelmann A, Liewald F, Brambs H . [Non-invasive, multi detector row (MDR) CT based computational fluid dynamics (CFD) analysis of hemodynamics in infrarenal abdominal aortic aneurysm (AAA) before and after endovascular repair]. Rofo. 2004; 176(1):56-61. DOI: 10.1055/s-2004-814667. View

3.
Liffman K, Lawrence-Brown M, Semmens J, Bui A, Rudman M, Hartley D . Analytical modeling and numerical simulation of forces in an endoluminal graft. J Endovasc Ther. 2001; 8(4):358-71. DOI: 10.1177/152660280100800405. View

4.
Frauenfelder T, Lotfey M, Boehm T, Wildermuth S . Computational fluid dynamics: hemodynamic changes in abdominal aortic aneurysm after stent-graft implantation. Cardiovasc Intervent Radiol. 2006; 29(4):613-23. DOI: 10.1007/s00270-005-0227-5. View

5.
Bonert M, Leask R, Butany J, Ethier C, Myers J, Johnston K . The relationship between wall shear stress distributions and intimal thickening in the human abdominal aorta. Biomed Eng Online. 2003; 2:18. PMC: 317350. DOI: 10.1186/1475-925X-2-18. View