Contrast-enhanced MR Imaging of the Brain Using T1-weighted FLAIR with BLADE Compared with a Conventional Spin-echo Sequence

Overview
Journal Eur Radiol
Specialty Radiology
Date 2007 Oct 9
PMID 17922279
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

The BLADE and PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) techniques have been proposed to reduce the effect of head motion. Preliminary results have shown that BLADE also reduces pulsation artifacts from venous sinuses. The purpose of this study was to compare T1-weighted FLAIR acquired with BLADE (T1W-FLAIR BLADE) and T1-weighted spin-echo (T1W-SE) for the detection of contrast enhancement in a phantom and in patients with suspected brain lesions and to compare the degree of flow-related artifacts in the patients. A phantom filled with diluted Gd-DTPA was scanned in addition to 27 patients. In the phantom study, the peak contrast-to-noise ratio of T1W-FLAIR BLADE was larger than that of T1W-SE, and the position of the peak was shifted to a lower concentration. In patients, the degree of flow-related artifacts was significantly higher in T1W-SE. Among the 27 patients, 9 had metastatic tumor, and 18 did not. On a patient-by-patient basis, the sensitivity and specificity for the detection of metastatic lesions on axial T1W-SE were 100% and 55.6% respectively, while on axial T1W-FLAIR BLADE they were 100% and 100%. T1W-FLAIR BLADE seems to be capable of replacing T1W-SE, at least for axial post-contrast imaging to detect brain metastases.

Citing Articles

Application of deep learning-based image reconstruction in MR imaging of the shoulder joint to improve image quality and reduce scan time.

Kaniewska M, Deininger-Czermak E, Getzmann J, Wang X, Lohezic M, Guggenberger R Eur Radiol. 2022; 33(3):1513-1525.

PMID: 36166084 PMC: 9935676. DOI: 10.1007/s00330-022-09151-1.


The detectability of brain metastases using contrast-enhanced spin-echo or gradient-echo images: a systematic review and meta-analysis.

Suh C, Jung S, Kim K, Pyo J J Neurooncol. 2016; 129(2):363-71.

PMID: 27324495 DOI: 10.1007/s11060-016-2185-y.


Intraventricular cerebrospinal fluid pulsation artifacts on low-field magnetic resonance imaging: Potential pitfall in diagnosis?.

Ogbole G, Soneye M, Okorie C, Sammet S Niger Med J. 2016; 57(1):59-63.

PMID: 27185981 PMC: 4859116. DOI: 10.4103/0300-1652.180565.


Elimination of motion and pulsation artifacts using BLADE sequences in shoulder MR imaging.

Lavdas E, Vlychou M, Zaloni E, Vassiou K, Tsagkalis A, Dailiana Z Skeletal Radiol. 2015; 44(11):1619-26.

PMID: 26306388 DOI: 10.1007/s00256-015-2232-3.


Contrast enhancement of intracranial lesions at 1.5 T: comparison among 2D spin echo, black-blood (BB) Cube, and BB Cube-FLAIR sequences.

Im S, Ashikaga R, Yagyu Y, Wakayama T, Miyoshi M, Hyodo T Eur Radiol. 2015; 25(11):3175-86.

PMID: 25929942 DOI: 10.1007/s00330-015-3757-5.


References
1.
Pipe J, Zwart N . Turboprop: improved PROPELLER imaging. Magn Reson Med. 2006; 55(2):380-5. DOI: 10.1002/mrm.20768. View

2.
Pipe J . Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med. 1999; 42(5):963-9. DOI: 10.1002/(sici)1522-2594(199911)42:5<963::aid-mrm17>3.0.co;2-l. View

3.
Forbes K, Pipe J, Karis J, Farthing V, Heiserman J . Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. AJNR Am J Neuroradiol. 2003; 24(5):794-8. PMC: 7975801. View

4.
Naganawa S, Koshikawa T, Nakamura T, Kawai H, Fukatsu H, Ishigaki T . Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T. Eur Radiol. 2004; 14(10):1901-8. DOI: 10.1007/s00330-004-2372-7. View

5.
Wintersperger B, Runge V, Biswas J, Nelson C, Stemmer A, Simonetta A . Brain magnetic resonance imaging at 3 Tesla using BLADE compared with standard rectilinear data sampling. Invest Radiol. 2006; 41(7):586-92. DOI: 10.1097/01.rli.0000223742.35655.24. View