Effect of a Nurse-implemented Sedation Protocol on the Incidence of Ventilator-associated Pneumonia
Overview
Emergency Medicine
Authors
Affiliations
Objective: To determine whether the use of a nurse-implemented sedation protocol could reduce the incidence of ventilator-associated pneumonia in critically ill patients.
Design: Two-phase (before-after), prospective, controlled study.
Setting: University-affiliated, 11-bed medical intensive care unit.
Patients: Patients requiring mechanical ventilation for >or=48 hrs and sedative infusion with midazolam or propofol alone.
Interventions: During the control phase, sedatives were adjusted according to the physician's decision. During the protocol phase, sedatives were adjusted according to a protocol developed by a multidisciplinary team including nurses and physicians. The protocol was based on the Cambridge scale, and sedation level was adjusted every 3 hrs by the nurses. Standard practices, including weaning from the ventilator and diagnosis of VAP, were the same during both study phases.
Measurements And Main Results: A total of 423 patients were enrolled (control group, n = 226; protocol group, n = 197). The incidence of VAP was significantly lower in the protocol group compared with the control group (6% and 15%, respectively, p = .005). By univariate analysis (log-rank test), only use of a nurse-implemented protocol was significantly associated with a decrease of incidence of VAP (p < .01). A nurse-implemented protocol was found to be independently associated with a lower incidence of VAP after adjustment on Simplified Acute Physiology Score II in the multivariate Cox proportional hazards model (hazard rate, 0.81; 95% confidence interval, 0.62-0.95; p = .03). The median duration of mechanical ventilation was significantly shorter in the protocol group (4.2 days; interquartile range, 2.1-9.5) compared with the control group (8 days; interquartile range, 2.2-22.0; p = .001), representing a 52% relative reduction. Extubation failure was more frequently observed in the control group compared with the protocol group (13% and 6%, respectively, p = .01). There was no significant difference in in-hospital mortality (38% vs. 45% in the protocol vs. control group, respectively, p = .22).
Conclusions: In patients receiving mechanical ventilation and requiring sedative infusions with midazolam or propofol, the use of a nurse-implemented sedation protocol decreases the rate of VAP and the duration of mechanical ventilation.
Stephens R, Evans E, Pajor M, Pappal R, Egan H, Wei M Crit Care. 2022; 26(1):179.
PMID: 35705989 PMC: 9198202. DOI: 10.1186/s13054-022-04042-9.
Stephens R, Evans E, Pajor M, Pappal R, Egan H, Wei M Res Sq. 2022; .
PMID: 35262073 PMC: 8902881. DOI: 10.21203/rs.3.rs-1389892/v1.
Hazwani T, Al Ahmady A, Kazzaz Y, Smari A, Al Enizy S, Alali H BMJ Open Qual. 2022; 11(1).
PMID: 34980589 PMC: 8724811. DOI: 10.1136/bmjoq-2021-001501.
Longrois D, Petitjeans F, Simonet O, De Kock M, Belliveau M, Pichot C Rom J Anaesth Intensive Care. 2021; 27(2):43-76.
PMID: 34056133 PMC: 8158317. DOI: 10.2478/rjaic-2020-0018.
Massaud-Ribeiro L, Barbosa M, Panisset A, Robaina J, Lima-Setta F, Prata-Barbosa A Rev Bras Ter Intensiva. 2021; 33(1):102-110.
PMID: 33886859 PMC: 8075341. DOI: 10.5935/0103-507X.20210011.