» Articles » PMID: 17720820

Development of Quantitative Real-time PCR Assays for Detection and Quantification of Surrogate Biological Warfare Agents in Building Debris and Leachate

Overview
Date 2007 Aug 28
PMID 17720820
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Evaluation of the fate and transport of biological warfare (BW) agents in landfills requires the development of specific and sensitive detection assays. The objective of the current study was to develop and validate SYBR green quantitative real-time PCR (Q-PCR) assays for the specific detection and quantification of surrogate BW agents in synthetic building debris (SBD) and leachate. Bacillus atrophaeus (vegetative cells and spores) and Serratia marcescens were used as surrogates for Bacillus anthracis (anthrax) and Yersinia pestis (plague), respectively. The targets for SYBR green Q-PCR assays were the 16S-23S rRNA intergenic transcribed spacer (ITS) region and recA gene for B. atrophaeus and the gyrB, wzm, and recA genes for S. marcescens. All assays showed high specificity when tested against 5 ng of closely related Bacillus and Serratia nontarget DNA from 21 organisms. Several spore lysis methods that include a combination of one or more of freeze-thaw cycles, chemical lysis, hot detergent treatment, bead beat homogenization, and sonication were evaluated. All methods tested showed similar threshold cycle values. The limit of detection of the developed Q-PCR assays was determined using DNA extracted from a pure bacterial culture and DNA extracted from sterile water, leachate, and SBD samples spiked with increasing quantities of surrogates. The limit of detection for B. atrophaeus genomic DNA using the ITS and B. atrophaeus recA Q-PCR assays was 7.5 fg per PCR. The limits of detection of S. marcescens genomic DNA using the gyrB, wzm, and S. marcescens recA Q-PCR assays were 7.5 fg, 75 fg, and 7.5 fg per PCR, respectively. Quantification of B. atrophaeus vegetative cells and spores was linear (R(2) > 0.98) over a 7-log-unit dynamic range down to 10(1) B. atrophaeus cells or spores. Quantification of S. marcescens (R(2) > 0.98) was linear over a 6-log-unit dynamic range down to 10(2) S. marcescens cells. The developed Q-PCR assays are highly specific and sensitive and can be used for monitoring the fate and transport of the BW surrogates B. atrophaeus and S. marcescens in building debris and leachate.

Citing Articles

Evaluation of sponge wipe surface sampling for collection of potential surrogates for non-spore-forming bioterrorism agents.

Aslett L, Calfee M, Monge M, Abdel-Hady A, Chamberlain T, Baartmans R J Appl Microbiol. 2024; 135(5).

PMID: 38609348 PMC: 11619258. DOI: 10.1093/jambio/lxae097.


Applications of polymerase chain reaction-based methods for the diagnosis of plague (Review).

Zhang Y, Wang Z, Wang W, Yu H, Jin M Exp Ther Med. 2022; 24(2):511.

PMID: 35837060 PMC: 9257939. DOI: 10.3892/etm.2022.11438.


Current Trends in the Biosensors for Biological Warfare Agents Assay.

Pohanka M Materials (Basel). 2019; 12(14).

PMID: 31323857 PMC: 6678440. DOI: 10.3390/ma12142303.


Molecular Assay for Detection of Genetic Markers Associated with Decreased Susceptibility to Cephalosporins in Neisseria gonorrhoeae.

Peterson S, Martin I, Demczuk W, Bharat A, Hoang L, Wylie J J Clin Microbiol. 2015; 53(7):2042-8.

PMID: 25878350 PMC: 4473228. DOI: 10.1128/JCM.00493-15.


Use of quantitative real-time PCR for direct detection of serratia marcescens in marine and other aquatic environments.

Joyner J, Wanless D, Sinigalliano C, Lipp E Appl Environ Microbiol. 2013; 80(5):1679-83.

PMID: 24375136 PMC: 3957607. DOI: 10.1128/AEM.02755-13.


References
1.
Ivnitski D, ONeil D, Gattuso A, Schlicht R, Calidonna M, Fisher R . Nucleic acid approaches for detection and identification of biological warfare and infectious disease agents. Biotechniques. 2003; 35(4):862-9. DOI: 10.2144/03354ss03. View

2.
Keswani J, Kashon M, Chen B . Evaluation of interference to conventional and real-time PCR for detection and quantification of fungi in dust. J Environ Monit. 2005; 7(4):311-8. DOI: 10.1039/b415498c. View

3.
Buttner M, Stetzenbach L . Enhanced detection of surface-associated bacteria in indoor environments by quantitative PCR. Appl Environ Microbiol. 2001; 67(6):2564-70. PMC: 92908. DOI: 10.1128/AEM.67.6.2564-2570.2001. View

4.
Johnson D, Lee P, Holmes V, Alvarez-Cohen L . An internal reference technique for accurately quantifying specific mRNAs by real-time PCR with application to the tceA reductive dehalogenase gene. Appl Environ Microbiol. 2005; 71(7):3866-71. PMC: 1169012. DOI: 10.1128/AEM.71.7.3866-3871.2005. View

5.
Higuchi R, Fockler C, Dollinger G, Watson R . Kinetic PCR analysis: real-time monitoring of DNA amplification reactions. Biotechnology (N Y). 1993; 11(9):1026-30. DOI: 10.1038/nbt0993-1026. View