Microbial Biofilm Formation in DUWS and Their Control Using Disinfectants
Overview
Authors
Affiliations
Objectives: Due to the presence of extended narrow bore tubing and long periods of stagnation, dental unit water systems (DUWs) can be prone to relatively high levels of microbial contamination, including the formation of biofilm and the presence of opportunistic pathogens, irrespective of the source and quality of the inflowing water. Whilst the European Union (EU) has yet to set a definitive microbiological guideline, the American Dental Association (ADA) has set a maximum of <200 colony forming units (cfu)/ml for DUWs water in the USA. The objective of this review is to discuss why microbial contamination and biofilms are so prevalent in DUWs, as well as the role of disinfectants and their potential for achieving microbial water quality levels recommended by the ADA.
Study Selection: The review outlines the principal factors responsible for biofilm formation in DUWs and a number of mechanisms used for microbial control.
Sources: The source material contained in this review is taken from the peer-reviewed literature.
Data: A variety of disinfectants are available for use, but controlled laboratory and clinical studies have shown that they can vary markedly in their efficacy and suitability for use. Some products have been shown to successfully remove biofilm and consistently reduce the microbial load of out-flowing water to <200 cfu/ml.
Conclusions: The effective delivery of approved disinfectants can control the level of microorganisms in DUWs at acceptable levels.
Mycobiology of Dental Unit Water: A Systematic Scoping Review.
Sobon N, Fakhruddin K, Samaranayake L, Remmani N, Mohammed M, Porntaveetus T Int Dent J. 2024; 75(1):86-99.
PMID: 39701921 PMC: 11806301. DOI: 10.1016/j.identj.2024.10.020.
Bacterial contamination of new dental unit waterlines and efficacy of shock disinfection.
Baudet A, Lizon J, Lozniewski A, Florentin A, Mortier E BMC Microbiol. 2024; 24(1):529.
PMID: 39695925 PMC: 11657442. DOI: 10.1186/s12866-024-03678-7.
Tolerance of biofilms to disinfectants commonly used in endoscope reprocessing?.
Leeb-Zatorska B, Van den Nest M, Ebner J, Moser D, Spettel K, Bovier-Azula L Biofilm. 2024; 8:100221.
PMID: 39430297 PMC: 11489157. DOI: 10.1016/j.bioflm.2024.100221.
Mohsin M, Avdic M, Fitzpatrick K, Lanzarini-Lopes M Microbiol Spectr. 2024; 12(6):e0004024.
PMID: 38687120 PMC: 11237523. DOI: 10.1128/spectrum.00040-24.
Initial waterline contamination by in newly installed dental chairs.
Baudet A, Lizon J, Florentin A, Mortier E Microbiol Spectr. 2024; 12(6):e0396223.
PMID: 38652098 PMC: 11237434. DOI: 10.1128/spectrum.03962-23.