» Articles » PMID: 32823641

Microbial Contamination of Dental Unit Waterlines and Potential Risk of Infection: A Narrative Review

Overview
Journal Pathogens
Date 2020 Aug 23
PMID 32823641
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Several studies have revealed that dental unit waterlines (DUWLs) are often contaminated by large numbers of various micro-organisms (bacteria, fungi, protozoa, viruses). Microbial contamination in DUWLs may originate from the mains water piped into the dental unit, the suck-back of patients' saliva into the line due to the lack of adequate valves, and contamination from bottled water systems. Some of the main determinants of microbial contamination in DUWLs are: a very small lumen size (0.5-2 mm) of the tubing used, high surface-to-volume ratio (6:1), low throughput and the materials of which the tubing is made, water stagnation outside of working hours. The environmental conditions present inside the conduits of the dental unit may facilitate the proliferation of micro-organisms and the consequent formation of biofilm on the interior surface of the pipes of DUWLs. During the use of handpieces, particularly high-speed rotating instruments, a spray is thrown up in the form of aerosols or spatters containing biological material (saliva, blood and dental plaque) and micro-organisms. This means that the health of both dental staff and patients could be at risk of infection. The risk of cross-infections in dental settings can be tackled by implementing combined interventions to prevent the contamination of DUWLs.

Citing Articles

Periodic detection and disinfection maintenance of dental unit waterlines in dental simulation head model laboratories.

Li B, Hu Y, Wang Y, Zhang C, Wang Z, Peng X Sci Rep. 2025; 15(1):5234.

PMID: 39939661 PMC: 11821815. DOI: 10.1038/s41598-025-89010-3.


In vitro evaluation of hypochlorous acid-silver nanoparticle waterline disinfectant for dental unit waterline disinfection.

Yin T, Li Q, Sun H, Zheng J, Wang Y, Luo Y BMC Chem. 2025; 19(1):25.

PMID: 39871300 PMC: 11773736. DOI: 10.1186/s13065-025-01382-9.


Effects of flushing of dental waterlines in portable dental units on water quality management.

Fushimi K, Watanabe J, Yamada M, Washio J, Takahashi N, Egusa H J Dent Sci. 2025; 19(Suppl 1):S61-S69.

PMID: 39807432 PMC: 11725118. DOI: 10.1016/j.jds.2024.10.014.


Metataxonomics study of dental bioaerosols affected by waterline disinfection.

Poolkerd W, Swatasuk B, Saengpitak M, Muangsawat S, Klankeo P, Thotsaporn K BMC Oral Health. 2024; 24(1):1575.

PMID: 39741231 PMC: 11689511. DOI: 10.1186/s12903-024-05304-4.


Mycobiology of Dental Unit Water: A Systematic Scoping Review.

Sobon N, Fakhruddin K, Samaranayake L, Remmani N, Mohammed M, Porntaveetus T Int Dent J. 2024; 75(1):86-99.

PMID: 39701921 PMC: 11806301. DOI: 10.1016/j.identj.2024.10.020.


References
1.
Volgenant C, Persoon I . Microbial water quality management of dental unit water lines at a dental school. J Hosp Infect. 2018; 103(1):e115-e117. DOI: 10.1016/j.jhin.2018.11.002. View

2.
Tall B, Williams H, George K, Gray R, Walch M . Bacterial succession within a biofilm in water supply lines of dental air-water syringes. Can J Microbiol. 1995; 41(7):647-54. DOI: 10.1139/m95-088. View

3.
Mainz J, Gerber A, Lorenz M, Michl R, Hentschel J, Nader A . Pseudomonas aeruginosa Acquisition in Cystic Fibrosis Patients in Context of Otorhinolaryngological Surgery or Dentist Attendance: Case Series and Discussion of Preventive Concepts. Case Rep Infect Dis. 2015; 2015:438517. PMC: 4381717. DOI: 10.1155/2015/438517. View

4.
Cicciu M . Water Contamination Risks at the Dental Clinic. Biology (Basel). 2020; 9(3). PMC: 7150821. DOI: 10.3390/biology9030043. View

5.
Miller R . Characteristics of blood-containing aerosols generated by common powered dental instruments. Am Ind Hyg Assoc J. 1995; 56(7):670-6. DOI: 10.1080/15428119591016683. View