» Articles » PMID: 17704168

Continuous Fluorescence Microphotolysis and Correlation Spectroscopy Using 4Pi Microscopy

Overview
Journal Biophys J
Publisher Cell Press
Specialty Biophysics
Date 2007 Aug 21
PMID 17704168
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Continuous fluorescence microphotolysis (CFM) and fluorescence correlation spectroscopy (FCS) permit measurement of molecular mobility and association reactions in single living cells. CFM and FCS complement each other ideally and can be realized using identical equipment. So far, the spatial resolution of CFM and FCS was restricted by the resolution of the light microscope to the micrometer scale. However, cellular functions generally occur on the nanometer scale. Here, we develop the theoretical and computational framework for CFM and FCS experiments using 4Pi microscopy, which features an axial resolution of approximately 100 nm. The framework, taking the actual 4Pi point spread function of the instrument into account, was validated by measurements on model systems, employing 4Pi conditions or normal confocal conditions together with either single- or two-photon excitation. In all cases experimental data could be well fitted by computed curves for expected diffusion coefficients, even when the signal/noise ratio was small due to the small number of fluorophores involved.

Citing Articles

Molecular diffusion and binding analyzed with FRAP.

Wachsmuth M Protoplasma. 2014; 251(2):373-82.

PMID: 24390250 DOI: 10.1007/s00709-013-0604-x.


Photonic methods to enhance fluorescence correlation spectroscopy and single molecule fluorescence detection.

Wenger J, Rigneault H Int J Mol Sci. 2010; 11(1):206-221.

PMID: 20162011 PMC: 2820999. DOI: 10.3390/ijms11010206.


Quantifying green fluorescent protein diffusion in Escherichia coli by using continuous photobleaching with evanescent illumination.

Slade K, Steele B, Pielak G, Thompson N J Phys Chem B. 2009; 113(14):4837-45.

PMID: 19296673 PMC: 2752987. DOI: 10.1021/jp810642d.


Limits for reduction of effective focal volume in multiple-beam light microscopy.

Arkhipov A, Schulten K Opt Express. 2009; 17(4):2861-70.

PMID: 19219190 PMC: 3160275. DOI: 10.1364/oe.17.002861.


4Pi microscopy of the nuclear pore complex.

Huve J, Wesselmann R, Kahms M, Peters R Biophys J. 2008; 95(2):877-85.

PMID: 18375513 PMC: 2440461. DOI: 10.1529/biophysj.107.127449.

References
1.
Yechiel E, Edidin M . Micrometer-scale domains in fibroblast plasma membranes. J Cell Biol. 1987; 105(2):755-60. PMC: 2114748. DOI: 10.1083/jcb.105.2.755. View

2.
Ries J, Schwille P . Studying slow membrane dynamics with continuous wave scanning fluorescence correlation spectroscopy. Biophys J. 2006; 91(5):1915-24. PMC: 1544284. DOI: 10.1529/biophysj.106.082297. View

3.
Jacobson K, Derzko Z, Wu E, Hou Y, Poste G . Measurement of the lateral mobility of cell surface components in single, living cells by fluorescence recovery after photobleaching. J Supramol Struct. 1976; 5(4):565(417)-576(428). DOI: 10.1002/jss.400050411. View

4.
Smith A, Slepchenko B, Schaff J, Loew L, Macara I . Systems analysis of Ran transport. Science. 2002; 295(5554):488-91. DOI: 10.1126/science.1064732. View

5.
Kubitscheck U, Kuckmann O, Kues T, Peters R . Imaging and tracking of single GFP molecules in solution. Biophys J. 2000; 78(4):2170-9. PMC: 1300809. DOI: 10.1016/S0006-3495(00)76764-6. View