Accuracy of Two Impression Techniques with Angulated Implants

Overview
Journal J Prosthet Dent
Specialty Dentistry
Date 2007 Jul 10
PMID 17618917
Citations 40
Authors
Affiliations
Soon will be listed here.
Abstract

Statement Of Problem: Accurate recording of implant locations is required so that definitive restorations are properly supported and do not place additional stress on the implants. Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast.

Purpose: The purpose of this study was to determine the effect the combined interaction of impression technique, implant angulation, and implant number has on the accuracy of implant definitive casts.

Material And Methods: One definitive stone cast was fabricated for each of 6 experimental groups and 1 control group. All 7 definitive casts had 3 implants arranged in a triangular pattern creating a plane. In the 6 experimental groups, the center implant was perpendicular to the plane of the cast while the outer implants had 5, 10, or 15 degrees convergence towards or divergence away from the center implant. The control definitive cast had all 3 implants parallel to each another and perpendicular to the plane of the cast. Five open tray and 5 closed tray addition silicone impressions were made of each definitive cast. Impressions were poured with type IV dental stone, and a fine tip measuring stylus was used to record multiple axis (X-Y-Z) coordinates on the top surface of the implant hex and on the cast base. Computer software was used to align the data sets and vector calculations determined the difference in degrees between the implant angles in the definitive cast and the duplicate casts. Statistical analysis used repeated-measures ANOVA (alpha=.05) with post-hoc tests of significant interactions.

Results: The angle errors for the closed and open tray impression techniques did not differ significantly (P=.22). Implant angulations and implant numbers differed in average angle errors but not in any easily interpreted pattern (P<.001). The combined interaction of impression technique, implant angulation, and implant number had no effect on the accuracy of the duplicate casts compared to the definitive casts (P=.19).

Conclusions: The average angle errors for the closed and open tray impression techniques did not differ significantly. There was no interpretable pattern of average angle errors in terms of implant angulation and implant number. The magnitude of distortion was similar for all combinations of impression technique, implant angulation, and implant number.

Citing Articles

Alterations in internal threads of implant analog of different materials after multiple reuse.

Laskar P, Mansuri A, Patel S, Kewalramani C, Sutradhar W, Karpathak S Bioinformation. 2024; 20(6):695-699.

PMID: 39131524 PMC: 11312318. DOI: 10.6026/973206300200695.


The Accuracy of Casts Obtained Using Different Impression Techniques and Impression Materials in Combined Parallel and Angulated Implants: An In Vitro Study.

V M, Chirom B, Gunadhar K, Priyadarshini S, Nongthombam R, P M Cureus. 2024; 16(4):e59193.

PMID: 38807829 PMC: 11131036. DOI: 10.7759/cureus.59193.


Evaluation of the Stability of Open-Tray Impression Coping Using Two Different Impression Materials at Three Different Subgingival Implant Placement Depths.

P M G, Sukumaran K, K H, Ravindran S Cureus. 2024; 16(5):e61117.

PMID: 38803409 PMC: 11129605. DOI: 10.7759/cureus.61117.


Comparative Accuracy of Intraoral and Extraoral Digital Workflows for Short Span Implant Supported Fixed Partial Denture Fabrication: An In Vitro Study.

Mansoor M, Sayed M, Abdul H, Zaidan M, Hakami T, Dighriri M Med Sci Monit. 2024; 30:e943706.

PMID: 38500254 PMC: 10960501. DOI: 10.12659/MSM.943706.


Influence of parallel pins on the angle deviation for placement of dental implants: an in vitro study.

Gonzalez Menendez H, Lorrio Castro J, Rodriguez Torres P, de la Vega Buro S, Zubizarreta-Macho A, Riad Deglow E BMC Oral Health. 2024; 24(1):134.

PMID: 38279099 PMC: 10811900. DOI: 10.1186/s12903-024-03883-w.