Intersubject and Intrasubject Variability of Gastric Volumes in Response to Isocaloric Liquid Meals in Functional Dyspepsia and Health
Overview
Neurology
Affiliations
Gastric emptying (GE) has a considerable variability, but data on reproducibility of gastric volume measurements are sparse. We aimed to study the reproducibility of postprandial gastric volume responses and GE using magnetic resonance imaging (MRI) in healthy controls (HC) and patients with functional dyspepsia (FD). Eight HC and eight FD patients underwent a MRI study on two occasions. MR images were acquired in seated position before and up to 120 min after liquid meal administration (200 mL, 300 kcal). Fasting (V0), initial postprandial stomach volumes (V1), volume changes (V1 - V0) and meal emptying half-times (T 1/2) were determined. Intersubject and intrasubject coefficients of variation (CV(inter), CV(intra)) and Pearson's correlation coefficients (r) were calculated. T 1/2 on both occasions were (mean +/- SD) 113 +/- 28 and 121 +/- 30 min in HC (ns) and 127 +/- 31 and 128 +/- 37 min in FD (ns), respectively. In HC, CV(inter), CV(intra), r were 31%, 23%, 0.49 for V0; 13%, 7%, 0.68 for V1; 10%, 4%, 0.71 for V1 - V0 and 25%, 7%, 0.90 for T 1/2. In FD these parameters were for V0: 42%, 41%, -0.06; for V1: 18%, 10%, 0.40; for V1 - V0: 20%, 14%, 0.74 and for T 1/2: 26%, 10%, 0.84. The stomach accommodates to a given meal volume, resulting in similar and reproducible postprandial volumes within- and between-subjects. MRI provides reproducible measurements of gastric volume responses in health and disease.
Zhang Y, Xie P, Li Y, Chen Z, Shi A Front Pharmacol. 2023; 14:1142003.
PMID: 37342592 PMC: 10277867. DOI: 10.3389/fphar.2023.1142003.
Bertoli D, Mark E, Liao D, Brock C, Frokjaer J, Drewes A Neurogastroenterol Motil. 2022; 35(2):e14497.
PMID: 36416084 PMC: 10078211. DOI: 10.1111/nmo.14497.
Non-uniform gastric wall kinematics revealed by 4D Cine magnetic resonance imaging in humans.
Sclocco R, Nguyen C, Staley R, Fisher H, Mendez A, Velez C Neurogastroenterol Motil. 2021; 33(8):e14146.
PMID: 33797166 PMC: 10315015. DOI: 10.1111/nmo.14146.
Comparison of manual and semiautomated techniques for analyzing gastric volumes with MRI in humans.
Bharucha A, Karwoski R, Fidler J, Holmes 3rd D, Robb R, Riederer S Am J Physiol Gastrointest Liver Physiol. 2014; 307(5):G582-7.
PMID: 25012844 PMC: 4182289. DOI: 10.1152/ajpgi.00048.2014.
Li G, Wang K, Chen R, Zhao H, Yang J, Zheng Q Acta Pharmacol Sin. 2012; 33(11):1359-71.
PMID: 23085739 PMC: 4011361. DOI: 10.1038/aps.2012.103.