» Articles » PMID: 17583816

[Toric Intraocular Lenses and Correction of Astigmatism]

Overview
Journal Ophthalmologe
Specialty Ophthalmology
Date 2007 Jun 23
PMID 17583816
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Toric intraocular lenses (tIOLs) have the potential to correct corneal astigmatism. The purpose of this review paper is: 1. to describe the biometric, keratometric and topographic conditions for implantion of tIOLs, 2. to highlight the advantages and disadvantages of tIOLs, 3. to define indications for and contraindications to tIOL implantation, 4. to provide clinical recommendations for the implantation of toric lenses, and 5. to report the specifications of all tIOLs that are currently available commercially.

Citing Articles

Comparative evaluation of rotational stability of toric IOLs with four-eyelet two-eyelet capsular tension rings in eyes with high myopia.

Jiang H, Liang K, Tao L Int J Ophthalmol. 2021; 14(3):378-382.

PMID: 33747812 PMC: 7930546. DOI: 10.18240/ijo.2021.03.07.


Efficacy of Toric intraocular lens implantation in eyes with high myopia: A prospective, case-controlled observational study.

Guo T, Gao P, Fang L, Guo L, Fan Y, Liu C Exp Ther Med. 2018; 15(6):5288-5294.

PMID: 29904411 PMC: 5996677. DOI: 10.3892/etm.2018.6102.


Long-term rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric IOL: a 1.5-year follow-up.

Gyongyossy B, Jirak P, Schonherr U Int J Ophthalmol. 2017; 10(4):573-578.

PMID: 28503430 PMC: 5406635. DOI: 10.18240/ijo.2017.04.12.


Cataract surgery with implantation of an artificial lens.

Kohnen T, Baumeister M, Kook D, Klaproth O, Ohrloff C Dtsch Arztebl Int. 2009; 106(43):695-702.

PMID: 19946433 PMC: 2780012. DOI: 10.3238/arztebl.2009.0695.


[The basics of refractive lens exchange].

Kohnen T, Klaproth O Ophthalmologe. 2008; 105(11):991-2, 994-8.

PMID: 18998146 DOI: 10.1007/s00347-008-1827-7.


References
1.
Langenbucher A, Seitz B, Kus M, Naumann G . Zernike representation of corneal topography height data after nonmechanical penetrating keratoplasty. Invest Ophthalmol Vis Sci. 1999; 40(3):582-91. View

2.
Seitz B, Langenbucher A . Intraocular lens power calculation in eyes after corneal refractive surgery. J Refract Surg. 2000; 16(3):349-61. DOI: 10.3928/1081-597X-20000501-09. View

3.
Bleckmann H, Keuch R . Implantation of spheric phakic posterior chamber intraocular lenses in astigmatic eyes. J Cataract Refract Surg. 2002; 28(5):805-9. DOI: 10.1016/s0886-3350(01)01126-9. View

4.
Langenbucher A, Seitz B, Viestenz A . [Impact of the eye's cyclorotation on axial orientation analysis of toric intraocular lenses: recommendations for an optimized evaluation of rotational stability of toric IOLs]. Klin Monbl Augenheilkd. 2006; 223(2):134-40. DOI: 10.1055/s-2005-858715. View

5.
Tehrani M, Dick H, Schwenn O, Blom E, Schmidt A, Koch H . Postoperative astigmatism and rotational stability after artisan toric phakic intraocular lens implantation. J Cataract Refract Surg. 2003; 29(9):1761-6. DOI: 10.1016/s0886-3350(03)00014-2. View