Continuous-flow Single-molecule CE with High Detection Efficiency

Overview
Journal Electrophoresis
Specialty Chemistry
Date 2007 Jun 20
PMID 17577880
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

This paper describes the use of two-beam line-confocal detection geometry for measuring the total mobility of individual molecules undergoing continuous-flow CE separation. High-sensitivity single-molecule confocal detection is usually performed with a diffraction limited focal spot (approximately 500 nm in diameter), which necessitates the use of nanometer-sized channels to ensure all molecules flow through the detection volume. To allow for the use of larger channels that are a few micrometers in width, we employed cylindrical optics to define a rectangular illumination area that is diffraction-limited (approximately 500 nm) in width, but a few micrometers in length to match the width of the microchannel. We present detailed studies that compare the performance of this line-confocal detection geometry with the more widely used point-confocal geometry. Overall, we found line-confocal detection to provide the highest combination of signal-to-background ratio and spatial detection efficiency when used with micrometer-sized channels. For example, in a 2 microm wide channel we achieved a 94% overall detection efficiency for single Alexa488 dye molecules when a 2 microm x 0.5 microm illumination area was used, but only 34% detection efficiency with a 0.5 microm-diameter detection spot. To carry out continuous-flow CE, we used two-beam fluorescent cross-correlation spectroscopy where the transit time of each molecule is determined by cross-correlating the fluorescence registered by two spatially offset line-confocal detectors. We successfully separated single molecules of FITC, FITC-tagged glutamate, and FITC-tagged glycine.

Citing Articles

Comparison of EV characterization by commercial high-sensitivity flow cytometers and a custom single-molecule flow cytometer.

Kim J, Xu S, Jung S, Nguyen A, Cheng Y, Zhao M J Extracell Vesicles. 2024; 13(8):e12498.

PMID: 39140467 PMC: 11322860. DOI: 10.1002/jev2.12498.


High-Throughput Counting and Superresolution Mapping of Tetraspanins on Exosomes Using a Single-Molecule Sensitive Flow Technique and Transistor-like Semiconducting Polymer Dots.

Jiang Y, Andronico L, Jung S, Chen H, Fujimoto B, Vojtech L Angew Chem Int Ed Engl. 2021; 60(24):13470-13475.

PMID: 33797851 PMC: 8215978. DOI: 10.1002/anie.202103282.


Sizing Extracellular Vesicles Using Membrane Dyes and a Single Molecule-Sensitive Flow Analyzer.

Andronico L, Jiang Y, Jung S, Fujimoto B, Vojtech L, Chiu D Anal Chem. 2021; 93(14):5897-5905.

PMID: 33784071 PMC: 10243643. DOI: 10.1021/acs.analchem.1c00253.


Single-Molecule Flow Platform for the Quantification of Biomolecules Attached to Single Nanoparticles.

Jung S, Han R, Sun W, Jiang Y, Fujimoto B, Yu J Anal Chem. 2018; 90(10):6089-6095.

PMID: 29672026 PMC: 5953847. DOI: 10.1021/acs.analchem.8b00024.


Prototyping of poly(dimethylsiloxane) interfaces for flow gating, reagent mixing, and tubing connection in capillary electrophoresis.

Zhang Q, Gong M J Chromatogr A. 2013; 1324:231-7.

PMID: 24331370 PMC: 4123544. DOI: 10.1016/j.chroma.2013.11.043.