Continuous-flow Single-molecule CE with High Detection Efficiency
Overview
Affiliations
This paper describes the use of two-beam line-confocal detection geometry for measuring the total mobility of individual molecules undergoing continuous-flow CE separation. High-sensitivity single-molecule confocal detection is usually performed with a diffraction limited focal spot (approximately 500 nm in diameter), which necessitates the use of nanometer-sized channels to ensure all molecules flow through the detection volume. To allow for the use of larger channels that are a few micrometers in width, we employed cylindrical optics to define a rectangular illumination area that is diffraction-limited (approximately 500 nm) in width, but a few micrometers in length to match the width of the microchannel. We present detailed studies that compare the performance of this line-confocal detection geometry with the more widely used point-confocal geometry. Overall, we found line-confocal detection to provide the highest combination of signal-to-background ratio and spatial detection efficiency when used with micrometer-sized channels. For example, in a 2 microm wide channel we achieved a 94% overall detection efficiency for single Alexa488 dye molecules when a 2 microm x 0.5 microm illumination area was used, but only 34% detection efficiency with a 0.5 microm-diameter detection spot. To carry out continuous-flow CE, we used two-beam fluorescent cross-correlation spectroscopy where the transit time of each molecule is determined by cross-correlating the fluorescence registered by two spatially offset line-confocal detectors. We successfully separated single molecules of FITC, FITC-tagged glutamate, and FITC-tagged glycine.
Kim J, Xu S, Jung S, Nguyen A, Cheng Y, Zhao M J Extracell Vesicles. 2024; 13(8):e12498.
PMID: 39140467 PMC: 11322860. DOI: 10.1002/jev2.12498.
Jiang Y, Andronico L, Jung S, Chen H, Fujimoto B, Vojtech L Angew Chem Int Ed Engl. 2021; 60(24):13470-13475.
PMID: 33797851 PMC: 8215978. DOI: 10.1002/anie.202103282.
Sizing Extracellular Vesicles Using Membrane Dyes and a Single Molecule-Sensitive Flow Analyzer.
Andronico L, Jiang Y, Jung S, Fujimoto B, Vojtech L, Chiu D Anal Chem. 2021; 93(14):5897-5905.
PMID: 33784071 PMC: 10243643. DOI: 10.1021/acs.analchem.1c00253.
Jung S, Han R, Sun W, Jiang Y, Fujimoto B, Yu J Anal Chem. 2018; 90(10):6089-6095.
PMID: 29672026 PMC: 5953847. DOI: 10.1021/acs.analchem.8b00024.
Zhang Q, Gong M J Chromatogr A. 2013; 1324:231-7.
PMID: 24331370 PMC: 4123544. DOI: 10.1016/j.chroma.2013.11.043.