Comparison of the Vitek Immunodiagnostic Assay System with an Indirect Immunoassay (Toxostat Test Kit) for Detection of Immunoglobulin G Antibodies to Toxoplasma Gondii in Clinical Specimens

Overview
Specialty Microbiology
Date 1991 Dec 1
PMID 1757547
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

The value and convenience of testing for specific anti-Toxoplasma gondii antibodies have led to the development of various antibody detection methods, such as the enzyme immunoassay. Two enzyme immunoassays, the Vitek Immuno-Diagnostic Assay System (VIDAS; Vitek Systems, Hazelwood, Mo.) and the Toxostat Test Kit (TST; Whittaker Bioproducts, Walkersville, Md.), were compared for their ability to detect T. gondii immunoglobulin G antibodies in fresh human sera. Specimens were tested according to the instructions of each manufacturer. Of 304 serum specimens tested, the results for 282 (93%) agreed in both assays (77 were positive and 205 were negative). The results for the remaining 22 (7%) specimens were discrepant; 20 of the 22 specimens tested low positive or equivocal by Toxostat and negative by VIDAS. Upon retesting, 8 of these 22 specimens were in concordance, increasing the level of agreement to 95.3%. Intra-assay reproducibility was tested with four to nine replicates of each of seven samples (four positive, one negative, and two equivocal) by both tests and six replicates of one standard by VIDAS. Coefficients of variation (CVs) for VIDAS were 6, 8, 10, 15, 18, 19, and 23% for the samples and 14% for the standard. For Toxostat the CVs were 2, 8, 10, 10, 13, and 16%. In general, CVs for VIDAS were slightly larger than the CVs for Toxostat. Day-to-day variability over 3 days was tested by VIDAS for only six samples (three positive, two negative, and one equivocal) and four standards; CVs ranged from 2 to 15% for the samples and from 6 to 13% for the standards. In conclusions, VIDAS is a rapid, convenient, non-labor-intensive, and easily performed test for the detection of immunoglobulin G antibodies to T. gondii in serum specimens.

Citing Articles

Detection of immunoglobulin G (IgG) and IgM antibodies to Toxoplasma gondii: evaluation of four commercial immunoassay systems.

Hofgartner W, Swanzy S, Bacina R, Condon J, Gupta M, Matlock P J Clin Microbiol. 1997; 35(12):3313-5.

PMID: 9399544 PMC: 230172. DOI: 10.1128/jcm.35.12.3313-3315.1997.


Evaluation of the second generation IMx Toxo IgG antibody assay for detection of antibodies to Toxoplasma gondii in human sera.

De Champs C, Pelloux H, Cambon M, Fricker-Hidalgo H, Goullier-Fleuret A, Ambroise-Thomas P J Clin Lab Anal. 1997; 11(4):214-9.

PMID: 9219063 PMC: 6760745. DOI: 10.1002/(sici)1098-2825(1997)11:4<214::aid-jcla7>3.0.co;2-8.


Determination of the optimal cutoff value for a serological assay: an example using the Johne's Absorbed EIA.

Ridge S, Vizard A J Clin Microbiol. 1993; 31(5):1256-61.

PMID: 8501227 PMC: 262914. DOI: 10.1128/jcm.31.5.1256-1261.1993.

References
1.
Sabin A, Feldman H . Dyes as Microchemical Indicators of a New Immunity Phenomenon Affecting a Protozoon Parasite (Toxoplasma). Science. 1948; 108(2815):660-3. DOI: 10.1126/science.108.2815.660. View

2.
Voller A, BIDWELL D, Bartlett A, FLECK D, Perkins M, Oladehin B . A microplate enzyme-immunoassay for toxoplasma antibody. J Clin Pathol. 1976; 29(2):150-3. PMC: 475993. DOI: 10.1136/jcp.29.2.150. View

3.
Van Enk R, James K, K D Thompson . Evaluation of three commercial enzyme immunoassays for toxoplasma and cytomegalovirus antibodies. Am J Clin Pathol. 1991; 95(3):428-34. DOI: 10.1093/ajcp/95.3.428. View

4.
Sluiters J, Balk A, Essed C, Mochtar B, Weimar W, Simoons M . Indirect enzyme-linked immunosorbent assay for immunoglobulin G and four immunoassays for immunoglobulin M to Toxoplasma gondii in a series of heart transplant recipients. J Clin Microbiol. 1989; 27(3):529-35. PMC: 267352. DOI: 10.1128/jcm.27.3.529-535.1989. View

5.
FLECK D . Annotation: Diagnosis of toxoplasmosis. J Clin Pathol. 1989; 42(2):191-3. PMC: 1141825. DOI: 10.1136/jcp.42.2.191. View