In Vivo Measurement of Subacromial Space Width During Shoulder Elevation: Technique and Preliminary Results in Patients Following Unilateral Rotator Cuff Repair

Overview
Date 2007 Jun 15
PMID 17560699
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The shoulder's subacromial space is of significant clinical interest due to its association with rotator cuff disease. Previous studies have estimated the subacromial space width to be 2-17 mm, but no study has measured in vivo subacromial space width during shoulder motion. The purpose of this study was to measure the in vivo subacromial space width during shoulder elevation in patients following rotator cuff repair.

Methods: Biplane X-ray images were collected during shoulder elevation of 11 patients who had undergone rotator cuff repair. Glenohumeral joint motion was measured from the biplane X-ray images for each subject's repaired and asymptomatic, contralateral shoulders. The joint motion data were combined with subject-specific CT models to measure the subacromial space width during shoulder motion.

Findings: Subacromial space width decreased with shoulder elevation, ranging from 2.3 to 7.4 mm in the repaired shoulder and 1.2-7.1 mm in the contralateral shoulder. Subacromial space width in the repaired shoulder was only 0.5 mm less than the contralateral shoulder when averaged over 10-60 degrees of glenohumeral elevation.

Interpretation: The results indicate that the humerus in the repaired shoulder is positioned more cranially on the glenoid than in the contralateral shoulder. It is unclear if these subtle differences in subacromial space width are due to the surgical procedure or post-operative stiffness, or if subacromial impingement contributed to the development of the rotator cuff tear. Future research will ascertain if these results represent a transient response to the surgery or a more fundamental difference in rotator cuff function between repaired and contralateral shoulders.

Citing Articles

The Effect of Low-Dose CT Protocols on Shoulder Model-Based Tracking accuracy Using Biplane Videoradiography.

Chen S, Lee E, Napier K, Rainbow M, Lawrence R Ann Biomed Eng. 2024; 53(2):481-491.

PMID: 39505762 PMC: 11805650. DOI: 10.1007/s10439-024-03645-3.


Effects of Scapular Angular Deviations on Potential for Rotator Cuff Tendon Mechanical Compression.

Lawrence R, Richardson L, Bilodeau H, Bonath D, Dahn D, Em M Orthop J Sports Med. 2024; 12(3):23259671231219023.

PMID: 38435717 PMC: 10906059. DOI: 10.1177/23259671231219023.


Investigating the reliability and validity of subacromial space measurements using ultrasound and MRI.

Boulanger S, Mahna A, Alenabi T, Gatti A, Culig O, Hynes L J Orthop Surg Res. 2023; 18(1):986.

PMID: 38135882 PMC: 10740303. DOI: 10.1186/s13018-023-04482-1.


Is the angular onset of pain during arm elevation associated to functioning in individuals with rotator cuff related shoulder pain?.

Noes G, Haik M, Pott-Junior H, Py Goncalves Barreto R, Ribeiro L, Rosa D Braz J Phys Ther. 2022; 26(3):100403.

PMID: 35487097 PMC: 9062240. DOI: 10.1016/j.bjpt.2022.100403.


Supraspinatus tendon thickness and subacromial impingement characteristics in younger and older adults.

Ishigaki T, Yoshino K, Hirokawa M, Sugawara M, Yamanaka M BMC Musculoskelet Disord. 2022; 23(1):234.

PMID: 35277147 PMC: 8915467. DOI: 10.1186/s12891-022-05179-y.


References
1.
Bigliani L, Levine W . Subacromial impingement syndrome. J Bone Joint Surg Am. 1997; 79(12):1854-68. View

2.
Tsai N, McClure P, Karduna A . Effects of muscle fatigue on 3-dimensional scapular kinematics. Arch Phys Med Rehabil. 2003; 84(7):1000-5. DOI: 10.1016/s0003-9993(03)00127-8. View

3.
Lehtinen J, Belt E, Lyback C, Kauppi M, Kaarela K, Kautiainen H . Subacromial space in the rheumatoid shoulder: a radiographic 15-year follow-up study of 148 shoulders. J Shoulder Elbow Surg. 2000; 9(3):183-7. View

4.
Budoff J, Nirschl R, Guidi E . Débridement of partial-thickness tears of the rotator cuff without acromioplasty. Long-term follow-up and review of the literature. J Bone Joint Surg Am. 1998; 80(5):733-48. DOI: 10.2106/00004623-199805000-00016. View

5.
Nawoczenski D, Clobes S, Gore S, Neu J, Olsen J, Borstad J . Three-dimensional shoulder kinematics during a pressure relief technique and wheelchair transfer. Arch Phys Med Rehabil. 2003; 84(9):1293-300. DOI: 10.1016/s0003-9993(03)00260-0. View