» Articles » PMID: 17553095

Simplified Low-copy-number DNA Analysis by Post-PCR Purification

Overview
Journal J Forensic Sci
Specialty Forensic Sciences
Date 2007 Jun 8
PMID 17553095
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Frequently, evidentiary items contain an insufficient quantity of DNA to obtain complete or even partial DNA profiles using standard forensic gentotyping techniques. Such low-copy-number (LCN) samples are usually subjected to increased amplification cylces to obtain genetic data. In this study, a 28-cycle polymerase chain reaction (PCR) was used to evaluate various methods of post-PCR purification for their effects on the sensitivity of fluorophore-based allelic detection subsequent to capillary electrophoretic separation. The amplified product was purified using filtration, silica gel membrane, and enzyme mediated hydrolysis purification techniques and evaluated for their effect on fluorescent allelic signal intensity. A purification method was selected and its effect on fluorescent allelic signal intensity was compared with that of the unpurified PCR product. A method of post-PCR purification is described which increases the sensitivity of standard 28-cycle PCR such that profiles from LCN DNA templates (<100 pg DNA) can be obtained. Full DNA profiles were consistently obtained with as little as 20 pg template DNA without increased cycle number. In mock case type samples with dermal ridge fingerprints, genetic profiles were obtained by amplification with 28 cycles followed by post-PCR purification whereas no profiles were obtained without purification of the PCR product. Allele dropout, increased stutter, and sporadic contamination typical of LCN analysis were observed; however, no contamination was observed in negative amplification controls. Post-PCR purification of the PCR product can increase the sensitivity of capillary electrophoresis to such an extent that DNA profiles can be obtained from <100 pg of DNA using 28-cycle amplification.

Citing Articles

A quantifiler™ trio-based HRM screening assay for the accurate prediction of single source versus mixed biological samples.

Torres D, Smith C, Williams A, Cox J, J Seashols-Williams S, Boone E Int J Legal Med. 2023; 137(6):1639-1651.

PMID: 37553510 DOI: 10.1007/s00414-023-03070-6.


Investigation of Linear Amplification Using Abasic Site-Containing Primers Coupled to Routine STR Typing for LT-DNA Analysis.

Qian X, Li Z, Zhou Z, Qian J, Yao Y, Shao C Genes (Basel). 2022; 13(8).

PMID: 36011297 PMC: 9407227. DOI: 10.3390/genes13081386.


Rapid DNA analysis for automated processing and interpretation of low DNA content samples.

Turingan R, Vasantgadkar S, Palombo L, Hogan C, Jiang H, Tan E Investig Genet. 2016; 7:2.

PMID: 26998214 PMC: 4797129. DOI: 10.1186/s13323-016-0033-7.


Reduced reaction volumes and increased Taq DNA polymerase concentration improve STR profiling outcomes from a real-world low template DNA source: telogen hairs.

McNevin D, Edson J, Robertson J, Austin J Forensic Sci Med Pathol. 2015; 11(3):326-38.

PMID: 25999132 DOI: 10.1007/s12024-015-9679-3.


Evaluation of methods to improve the extraction and recovery of DNA from cotton swabs for forensic analysis.

Adamowicz M, Stasulli D, Sobestanovich E, Bille T PLoS One. 2014; 9(12):e116351.

PMID: 25549111 PMC: 4280208. DOI: 10.1371/journal.pone.0116351.