Abstract

Objective: In patients with postoperative wound dehiscence in the presence of infection, extensive visceral oedema often necessitates mechanical containment of bowel. Prosthetic mesh is often used for this purpose. The aim of the present study was to assess the safety of the use of non-absorbable and absorbable meshes for this purpose.

Method: All patients that had undergone mesh repair of abdominal wound dehiscence between January 1988 and January 1998 in the presence of intra-abdominal infection were included in a retrospective cohort study. All surviving patients had physical follow-up in February 2001.

Result: Eighteen patients were included in the study. Meshes consisted of polyglactin (n = 6), polypropylene (n = 8), polyester (n = 1), or a combination of a polypropylene mesh with a polyglactin mesh on the visceral side (n = 3). All patients developed complications, consisting mainly of mesh infection (77%), intra-abdominal abscess (17%), enterocutaneous fistula (17%), or mesh migration through the bowel (11%). Mesh removal was necessary in eight patients (44%). Within four months postoperatively, six patients (33%) had died because of progressive abdominal sepsis. The incidence of progressive abdominal sepsis was significantly higher in the group with absorbable polyglactin mesh than in the group with nonabsorbable mesh (67 vs. 11%, p = 0.02) After a mean follow-up of 49 months, 63% of the surviving patients had developed incisional hernia. Absorbable meshes did not yield better outcomes than nonabsorbable meshes in terms of complications and mortality rate.

Conclusion: Synthetic graft placement in the presence of intra-abdominal infection has a high risk of complications, regardless of whether absorbable (polyglactin) or non-absorbable mesh material (polypropylene or polyester) is used, and should be avoided if possible.

Citing Articles

Meshing around: high-risk hernias and infected mesh.

Keric N, Campbell A Trauma Surg Acute Care Open. 2024; 9(Suppl 2):e001379.

PMID: 38646030 PMC: 11029232. DOI: 10.1136/tsaco-2024-001379.


Xenogeneic Mesh Provides Safe and Durable Long-Term Outcomes in Abdominal Wall Reconstruction of High-Risk Centers for Disease Control and Prevention Class III and IV Defects.

Hassan A, Asaad M, Liu J, Offodile 2nd A, Butler C Ann Surg Open. 2023; 3(2):e152.

PMID: 37601613 PMC: 10431562. DOI: 10.1097/AS9.0000000000000152.


Hernia Prevention Using Biologic Mesh and/or Small Bites: A Multispecialty 2 × 2 Factorial Randomized Controlled Trial.

Coelho R, Dhanani N, Lyons N, Bernardi K, Askenasy E, Millas S J Am Coll Surg. 2023; 237(2):309-317.

PMID: 37458369 PMC: 10574223. DOI: 10.1097/XCS.0000000000000705.


Predictors for surgical site infection in patients undergoing therapeutic or prophylactic intra-abdominal onlay mesh (IPOM) implantation in clean and contaminated surgical fields.

Jakob M, Bruggemann A, Moser N, Candinas D, Beldi G, Haltmeier T Surg Endosc. 2023; 37(9):6885-6894.

PMID: 37311892 PMC: 10462502. DOI: 10.1007/s00464-023-10144-4.


A prospective multicentre study evaluating the outcomes of the abdominal wall dehiscence repair using posterior component separation with transversus abdominis muscle release reinforced by a retro-muscular mesh: filling a step.

Habeeb T, Hussain A, Shelat V, Chiaretti M, Bueno-Lledo J, Garcia Fadrique A World J Emerg Surg. 2023; 18(1):15.

PMID: 36869364 PMC: 9985288. DOI: 10.1186/s13017-023-00485-9.


References
1.
Patton Jr J, Berry S, Kralovich K . Use of human acellular dermal matrix in complex and contaminated abdominal wall reconstructions. Am J Surg. 2007; 193(3):360-3. DOI: 10.1016/j.amjsurg.2006.09.021. View

2.
Porter J . A combination of Vicryl and Marlex mesh: a technique for abdominal wall closure in difficult cases. J Trauma. 1995; 39(6):1178-80. DOI: 10.1097/00005373-199512000-00031. View

3.
Osther P, Gjode P, Mortensen B, Mortensen P, Bartholin J, Gottrup F . Randomized comparison of polyglycolic acid and polyglyconate sutures for abdominal fascial closure after laparotomy in patients with suspected impaired wound healing. Br J Surg. 1995; 82(8):1080-2. DOI: 10.1002/bjs.1800820824. View

4.
Turkcapar A, Yerdel M, Aydinuraz K, Bayar S, Kuterdem E . Repair of midline incisional hernias using polypropylene grafts. Surg Today. 1998; 28(1):59-63. DOI: 10.1007/BF02483609. View

5.
Miller P, Thompson J, Faler B, Meredith J, Chang M . Late fascial closure in lieu of ventral hernia: the next step in open abdomen management. J Trauma. 2002; 53(5):843-9. DOI: 10.1097/00005373-200211000-00007. View