Numerical Simulation of Cardiovascular Dynamics with Different Types of VAD Assistance

Overview
Journal J Biomech
Specialty Physiology
Date 2007 Apr 17
PMID 17433816
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

A variety of methods by which mechanical circulatory support (MCS) can be provided have been described. However, the haemodynamic benefits of the different methods have not been adequately quantified. The aim of this paper is to compare the haemodynamic effects of six forms of MCS by numerical simulation. Three types of ventricular assist device (VAD) are studied: positive displacement; impeller and a novel reciprocating-valve design. Similarly, three pumping modes are modelled: constant flow; counterpulsation and copulsation. The cardiovascular system is modelled using an approach developed previously, using the concentrated parameter method by considering flow resistance, vessel elasticity and inertial effects of blood in individual conduit segments. The dynamic modelling of displacement and impeller pumps is represented by VAD inlet/outlet flow-rate changes. The dynamics of the reciprocating-valve pump is modelled with a specified displacement profile. Results show that in each simulation, the physiological variables of mean arterial pressure and systemic flow are adequately maintained. Modulation of the impeller pump flow profile produces a small (5 mmHg) oscillatory component to arterial pressure, whereas the displacement and reciprocating-valve pumps generate substantial arterial pressure and flow pulsatility. The impeller pump requires the least power input, the reciprocating valve pump slightly more, and the displacement pump the most. The in parallel configuration of the impeller and displacement pump designs with respect to the left ventricle provides near complete unloading and can cause the aortic valve to remain closed throughout the entire cardiac cycle with the attendant risk of aortic valve leaflet fusion following prolonged support. The in series configuration of the reciprocating-valve pump avoids this shortcoming but activation must be carefully synchronized to the cardiac cycle to allow adequate coronary perfusion. The reciprocating-valve pump is associated with haemodynamic advantages and a favourable power consumption.

Citing Articles

Evaluation of Different Cannulation Strategies for Aortic Arch Surgery Using a Cardiovascular Numerical Simulator.

De Lazzari B, Capoccia M, Cheshire N, Rosendahl U, Badagliacca R, De Lazzari C Bioengineering (Basel). 2023; 10(1).

PMID: 36671632 PMC: 9854437. DOI: 10.3390/bioengineering10010060.


Simulated Performance of the Cleveland Clinic Continuous-Flow Total Artificial Heart Using the Virtual Mock Loop.

Miyamoto T, Horvath D, Horvath D, Karimov J, Byram N, Kuban B ASAIO J. 2018; 65(6):565-572.

PMID: 30074965 PMC: 6359994. DOI: 10.1097/MAT.0000000000000857.


Simulation as a preoperative planning approach in advanced heart failure patients. A retrospective clinical analysis.

Capoccia M, Marconi S, Singh S, Pisanelli D, De Lazzari C Biomed Eng Online. 2018; 17(1):52.

PMID: 29720187 PMC: 5930731. DOI: 10.1186/s12938-018-0491-7.


Windkessel model of hemodynamic state supported by a pulsatile ventricular assist device in premature ventricle contraction.

Her K, Kim J, Lim K, Choi S Biomed Eng Online. 2018; 17(1):18.

PMID: 29394944 PMC: 5797383. DOI: 10.1186/s12938-018-0440-5.


Effect of counter-pulsation control of a pulsatile left ventricular assist device on working load variations of the native heart.

Choi S, Nam K, Lim K, Shim E, Won Y, Woo H Biomed Eng Online. 2014; 13(1):35.

PMID: 24708625 PMC: 3976558. DOI: 10.1186/1475-925X-13-35.