» Articles » PMID: 17418189

Anodic Stripping Voltammetry of Antimony Using Gold Nanoparticle-modified Carbon Screen-printed Electrodes

Overview
Journal Anal Chim Acta
Publisher Elsevier
Specialty Chemistry
Date 2007 Apr 10
PMID 17418189
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Carbon screen-printed electrodes (CSPE) modified with gold nanoparticles present an interesting alternative in the determination of antimony using differential pulse anodic stripping voltammetry. Metallic gold nanoparticles deposits have been obtained by direct electrochemical deposition. Scanning electron microscopy measurements show that the electrochemically synthesized gold nanoparticles are deposited in aggregated form. Any undue effects caused by the presence of foreign ions in the solution were also analyzed to ensure that common interferents in the determination of antimony by ASV. The detection limit for Sb(III) obtained was 9.44 x 10(-10) M. In terms of reproducibility, the precision of the above mentioned method in %R.S.D. values was calculated at 2.69% (n=10). The method was applied to determine levels of antimony in seawater samples and pharmaceutical preparations.

Citing Articles

Electrospun Polymer Nanofibers Decorated with Noble Metal Nanoparticles for Chemical Sensing.

Chen C, Tang Y, Vlahovic B, Yan F Nanoscale Res Lett. 2017; 12(1):451.

PMID: 28704979 PMC: 5505893. DOI: 10.1186/s11671-017-2216-4.


Recent Advances in the Fabrication and Application of Screen-Printed Electrochemical (Bio)Sensors Based on Carbon Materials for Biomedical, Agri-Food and Environmental Analyses.

Hughes G, Westmacott K, Honeychurch K, Crew A, Pemberton R, Hart J Biosensors (Basel). 2016; 6(4).

PMID: 27690118 PMC: 5192370. DOI: 10.3390/bios6040050.


Effect of Nanoparticles on Modified Screen Printed Inhibition Superoxide Dismutase Electrodes for Aluminum.

Barquero-Quiros M, Arcos-Martinez M Sensors (Basel). 2016; 16(10).

PMID: 27681735 PMC: 5087377. DOI: 10.3390/s16101588.


A chronoamperometric screen printed carbon biosensor based on alkaline phosphatase inhibition for W(IV) determination in water, using 2-phospho-L-ascorbic acid trisodium salt as a substrate.

Alvarado-Gamez A, Alonso-Lomillo M, Dominguez-Renedo O, Arcos-Martinez M Sensors (Basel). 2015; 15(2):2232-43.

PMID: 25621602 PMC: 4367303. DOI: 10.3390/s150202232.


Acetylcholinesterase inhibition-based biosensor for aluminum(III) chronoamperometric determination in aqueous media.

Barquero-Quiros M, Dominguez-Renedo O, Alonso-Lomillo M, Arcos-Martinez M Sensors (Basel). 2014; 14(5):8203-16.

PMID: 24811076 PMC: 4063056. DOI: 10.3390/s140508203.