» Articles » PMID: 17386545

Selectivity Enhancement of Anion-responsive Electrodes by Pulsed Chronopotentiometry

Overview
Journal Anal Chim Acta
Publisher Elsevier
Specialty Chemistry
Date 2007 Mar 28
PMID 17386545
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

A large and robust selectivity improvement of ion-selective electrodes is presented for the measurement of abundant ions. An improvement in selectivity by more than two orders of magnitude has been attained for the hydrophilic chloride ions measured in a dilute background of the lipophilic ions perchlorate and salicylate in a pulsed chronopotentiometric measurement mode. This is attributed to a robust kinetic discrimination of the dilute lipophilic ions in this measuring mode, which is not possible to achieve in classical potentiometry. Maximum tolerable concentrations of the interfering ions are found to be on the order of 30 microM before causing substantial changes in potential. As an example of practical relevance, the robust detection of chloride in 72 microM salicylate (reflecting 1:10 diluted blood) with a detection limit of 0.5 mM chloride is demonstrated. Corresponding potentiometric sensors did not give a useful chloride response under these conditions.

Citing Articles

Conducting polymer functionalization in search of advanced materials in ionometry: ion-selective electrodes and optodes.

Imali D, Perera E, Kaumal M, Dissanayake D RSC Adv. 2024; 14(35):25516-25548.

PMID: 39139237 PMC: 11321474. DOI: 10.1039/d4ra02615b.


Nonequilibrium Anion Detection in Solid-Contact Ion-Selective Electrodes.

Gettler R, Mehregan S, Koenig H, Kaess A, Young M ACS Omega. 2024; 9(14):16443-16457.

PMID: 38617695 PMC: 11007695. DOI: 10.1021/acsomega.4c00131.


All-solid-state chip utilizing molecular imprinted polymer for erythromycin detection in milk samples: Printed circuit board-based potentiometric system.

Tantawy M, Yehia A, Elbalkiny H Mikrochim Acta. 2023; 190(10):408.

PMID: 37733266 PMC: 10514120. DOI: 10.1007/s00604-023-05959-w.


Integration of an Aerosol-Assisted Deposition Technique for the Deposition of Functional Biomaterials Applied to the Fabrication of Miniaturised Ion Sensors.

Ruiz-Gonzalez A, Choy K Nanomaterials (Basel). 2021; 11(4).

PMID: 33916937 PMC: 8067610. DOI: 10.3390/nano11040938.


Selectivity Enhancement for Chloride Ion by In(III)-Porphyrin-Based Polymeric Membrane Electrode Operated in Pulsed Chronopotentiometric Mode.

Gemene K, Meyerhoff M Electroanalysis. 2013; 24(3):643-648.

PMID: 23355767 PMC: 3553400. DOI: 10.1002/elan.201200021.


References
1.
Shvarev A, Bakker E . Distinguishing free and total calcium with a single pulsed galvanostatic ion-selective electrode. Talanta. 2008; 63(1):195-200. DOI: 10.1016/j.talanta.2003.10.010. View

2.
Berrocal M, Cruz A, Badr I, Bachas L . Tripodal ionophore with sulfate recognition properties for anion-selective electrodes. Anal Chem. 2000; 72(21):5295-9. DOI: 10.1021/ac000241p. View

3.
Xu Y, De Marco R, Shvarev A, Bakker E . Reversible electrochemical monitoring of surface confined reactions at liquid-liquid interfaces by modulation of ion transfer fluxes. Chem Commun (Camb). 2005; (24):3074-6. DOI: 10.1039/b503548a. View

4.
Shvarev A, Bakker E . Response characteristics of a reversible electrochemical sensor for the polyion protamine. Anal Chem. 2005; 77(16):5221-8. DOI: 10.1021/ac050101l. View

5.
Bakker E, Meruva R, Pretsch E, Meyerhoff M . Selectivity of polymer membrane-based ion-selective electrodes: self-consistent model describing the potentiometric response in mixed ion solutions of different charge. Anal Chem. 1994; 66(19):3021-30. DOI: 10.1021/ac00091a600. View