Abstract

Objective: Reliable and rapid delineation of arteriovenous malformations enables the application of effective treatments such as stereotactic radiosurgery. We describe a new method to improve the speed and reliability of visualizing the flow of contrast images with digital subtraction angiography.

Methods: In line with current practices, digital subtraction angiography was used to produce a sequence of grayscale images. The new method combines the standard grayscale images produced by digital subtraction angiography into a single composite color image that encodes the contrast arrival time at each point of the brain's circulatory system. The algorithm is simple, fast, and easy to implement.

Results: The technique allows the flow of contrast from a series of angiography images to be summarized in a single color image.

Conclusion: This visualization method promises to improve the speed of manual delineation of arteriovenous malformations. Further studies are required to evaluate the clinical value of the use of color intensity projection images, supplemented by grayscale images as necessary, in comparison with contouring on grayscale images only.

Citing Articles

Experimental study using phantom models of cerebral aneurysms and 4D-DSA to measure blood flow on 3D-color-coded images.

Fujimura S, Yamanaka Y, Kan I, Nagao M, Otani K, Karagiozov K Technol Health Care. 2024; 32(5):3217-3230.

PMID: 38968064 PMC: 11492053. DOI: 10.3233/THC-231906.


Peri-therapeutic multi-modal hemodynamic assessment and detection of predictors for symptomatic in-stent restenosis after percutaneous transluminal angioplasty and stenting.

Song X, Qiu H, Yang S, Liu Y, Cao Y, Wang S Front Neurol. 2023; 14:1136847.

PMID: 37144006 PMC: 10151536. DOI: 10.3389/fneur.2023.1136847.


Feasibility of a silicone vascular phantom replicating real arterial contrast filling dynamics on cerebral angiography: An in-vitro pilot study.

Lee K, Sheen J, Yoon J, Kim M, Maeng J, Hwang S PLoS One. 2023; 18(1):e0280395.

PMID: 36649351 PMC: 9844885. DOI: 10.1371/journal.pone.0280395.


Color-Mapping of 4D-CTA for the Detection of Cranial Arteriovenous Shunts.

Meijs M, Pegge S, Murayama K, Boogaarts H, Prokop M, Willems P AJNR Am J Neuroradiol. 2019; 40(9):1498-1504.

PMID: 31395664 PMC: 7048455. DOI: 10.3174/ajnr.A6156.


Peritherapeutic Hemodynamic Changes of Carotid Stenting Evaluated with Quantitative DSA in Patients with Carotid Stenosis.

Teng M, Chang F, Lin C, Chiang L, Hong J, Kao Y AJNR Am J Neuroradiol. 2016; 37(10):1883-1888.

PMID: 27173363 PMC: 7960484. DOI: 10.3174/ajnr.A4813.