Simultaneous B1 + Homogenization and Specific Absorption Rate Hotspot Suppression Using a Magnetic Resonance Phased Array Transmit Coil
Overview
Authors
Affiliations
In high-field MRI severe problems with respect to B(1) (+) uniformity and specific absorption rate (SAR) deposition pose a great challenge to whole-body imaging. In this study the potential of a phased array transmit coil is investigated to simultaneously reduce B(1) (+) nonuniformity and SAR deposition. This was tested by performing electromagnetic simulations of a phased array TEM coil operating at 128 MHz loaded with two different homogeneous elliptical phantoms and four dielectric patient models. It was shown that the wave interference of a circularly polarized RF field with an ellipse and a pelvis produces largely identical B(1) (+) and electric field patterns. Especially for obese patients, this results in large B(1) (+) nonuniformity and global areas with elevated SAR deposition. It is demonstrated that a phased array transmit coil can reduce these phenomena. The technique was especially successful in suppressing SAR hotspots with a decrease up to 50%. The application of optimized settings for an ellipse to the patient models leads to comparable results as obtained with the patient-specific optimizations. This suggests that generic phase/amplitude port settings are possible, requiring no preinformation about patient-specific RF fields. Such a scheme would, due to its simultaneous B(1) (+) homogenization and extra SAR margin, have many benefits for whole-body imaging at 3 T.
Average SAR prediction, validation, and evaluation for a compact MR scanner head-sized RF coil.
Tarasek M, Shu Y, Kang D, Tao S, Gray E, Huston 3rd J Magn Reson Imaging. 2021; 85:168-176.
PMID: 34666159 PMC: 8631045. DOI: 10.1016/j.mri.2021.10.011.
Rausch I, Valladares A, Sundar L, Beyer T, Hacker M, Meyerspeer M EJNMMI Phys. 2021; 8(1):18.
PMID: 33599876 PMC: 7892652. DOI: 10.1186/s40658-021-00364-9.
Temperature-based MRI safety simulations with a limited number of tissues.
Carluccio G, Akgun C, Vaughan J, Collins C Magn Reson Med. 2021; 86(1):543-550.
PMID: 33547673 PMC: 8193628. DOI: 10.1002/mrm.28693.
Volzke Y, Pracht E, Hattingen E, Tse D, Stocker T MAGMA. 2020; 34(3):427-436.
PMID: 32865653 PMC: 8154804. DOI: 10.1007/s10334-020-00879-9.
MRI safety risks in the obese: The case of the disposable lighter stored in the pannus.
Gach H, Mackey S, Hausman S, Jackson D, Benzinger T, Henke L Radiol Case Rep. 2019; 14(5):634-638.
PMID: 30923590 PMC: 6424094. DOI: 10.1016/j.radcr.2019.02.023.