» Authors » Cornelis A T van den Berg

Cornelis A T van den Berg

Explore the profile of Cornelis A T van den Berg including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 158
Citations 2088
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Schilder M, Mandija S, Jacobs S, Kleinloog J, Liu H, van der Heide O, et al.
MAGMA . 2025 Mar; PMID: 40035911
Objective: To report T/T-values of normal and normal appearing brain tissues (NBTs, healthy volunteers; NABTs, patients) acquired with a whole-brain 5-minute Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) protocol, and...
2.
Jung K, Meerbothe T, Meerbothe T, Cui C, Park M, van den Berg C, et al.
Neuroimage . 2025 Jan; 307:121054. PMID: 39863005
Magnetic resonance electrical properties tomography can extract the electrical properties of in-vivo tissue. To estimate tissue electrical properties, various reconstruction algorithms have been proposed. However, physics-based reconstructions are prone to...
3.
Liu H, Versteeg E, Fuderer M, van der Heide O, Schilder M, van den Berg C, et al.
Magn Reson Med . 2024 Nov; 93(5):2008-2019. PMID: 39607873
Purpose: Current three-dimensional (3D) MR Spin TomogrAphy in Time-Domain (MR-STAT) protocols use transient-state, gradient-spoiled gradient-echo sequences that are prone to cerebrospinal fluid (CSF) pulsation artifacts when applied to the brain....
4.
Xu F, Mandija S, Kleinloog J, Liu H, van der Heide O, van der Kolk A, et al.
MAGMA . 2024 Aug; 37(6):1021-1030. PMID: 39180686
Objective: The image quality of synthetized FLAIR (fluid attenuated inversion recovery) images is generally inferior to its conventional counterpart, especially regarding the lesion contrast mismatch. This work aimed to improve...
5.
McGrory M, Versteeg E, Sbrizzi A, van den Berg C, Klomp D, Siero J
Magn Reson Med . 2024 Aug; 92(6):2734-2748. PMID: 39099149
Purpose: To demonstrate the feasibility of using a nonlinear gradient field for spatial encoding at the ultrasonic switching frequency of 20 kHz and present a framework to reconstruct data acquired...
6.
Zumbo S, Mandija S, Meliado E, Stijnman P, Meerbothe T, van den Berg C, et al.
IEEE Open J Eng Med Biol . 2024 Jul; 5:505-513. PMID: 39050972
Magnetic Resonance imaging based Electrical Properties Tomography (MR-EPT) is a non-invasive technique that measures the electrical properties (EPs) of biological tissues. In this work, we present and numerically investigate the...
7.
Eijbersen M, Steensma B, van den Berg C, Raaijmakers A
Magn Reson Med . 2024 Jun; 92(5):2246-2260. PMID: 38860561
Purpose: A previously published method for MRI-based transfer function assessment makes use of the so-called transceive phase assumption (TPA). This limits its applicability to shorter leads and/or lower field strengths....
8.
van der Heide O, van den Berg C, Sbrizzi A
Magn Reson Med . 2024 Mar; 92(2):618-630. PMID: 38441315
Purpose: MR-STAT is a relatively new multiparametric quantitative MRI technique in which quantitative paramater maps are obtained by solving a large-scale nonlinear optimization problem. Managing reconstruction times is one of...
9.
Kolenbrander I, Maspero M, Hendriksen A, Pollitt R, van der Voort van Zyp J, van den Berg C, et al.
Med Phys . 2024 Feb; 51(4):2367-2377. PMID: 38408022
Background: Deep learning-based unsupervised image registration has recently been proposed, promising fast registration. However, it has yet to be adopted in the online adaptive magnetic resonance imaging-guided radiotherapy (MRgRT) workflow....
10.
Versteeg E, Liu H, van der Heide O, Fuderer M, van den Berg C, Sbrizzi A
Magn Reson Med . 2024 Feb; 92(1):226-235. PMID: 38326909
Purpose: To demonstrate the feasibility and robustness of the Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) framework for fast, high SNR relaxometry at 7T. Methods: To deploy MR-STAT on 7T-systems,...