» Articles » PMID: 17296700

Technologies for Guidance of Radiofrequency Ablation in the Multimodality Interventional Suite of the Future

Abstract

Several new image-guidance tools and devices are being prototyped, investigated, and compared. These tools are introduced and include prototype software for image registration and fusion, thermal modeling, electromagnetic tracking, semiautomated robotic needle guidance, and multimodality imaging. The integration of treatment planning with computed tomography robot systems or electromagnetic needle-tip tracking allows for seamless, iterative, "see-and-treat," patient-specific tumor ablation. Such automation, navigation, and visualization tools could eventually optimize radiofrequency ablation and other needle-based ablation procedures and decrease variability among operators, thus facilitating the translation of novel image-guided therapies. Much of this new technology is in use or will be available to the interventional radiologist in the near future, and this brief introduction will hopefully encourage research in this emerging area.

Citing Articles

Tissue Ablation: Applications and Perspectives.

Keum H, Cevik E, Kim J, Demirlenk Y, Atar D, Saini G Adv Mater. 2024; 36(32):e2310856.

PMID: 38771628 PMC: 11309902. DOI: 10.1002/adma.202310856.


Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation.

Liu L, Pua R, Rosario-Berrios D, Sandvold O, Perkins A, Cormode D Phys Med Biol. 2024; 69(4).

PMID: 38252974 PMC: 10839467. DOI: 10.1088/1361-6560/ad2124.


Smartphone application with 3D-printed needle guide for faster and more accurate CT-guided interventions in a phantom.

Lui C, Polster R, Bullen J, Baqui Z, Ilaslan H, Neill M Skeletal Radiol. 2023; 53(3):567-573.

PMID: 37725165 DOI: 10.1007/s00256-023-04453-x.


Procedural Software Toolkit in the Armamentarium of Interventional Therapies: A Review of Additive Usefulness and Current Evidence.

Al-Sharydah A, BinShaiq F, Aloraifi R, Almefleh A, Alessa S, Alobud A Diagnostics (Basel). 2023; 13(4).

PMID: 36832254 PMC: 9955934. DOI: 10.3390/diagnostics13040765.


Fiber-Optic Distributed Sensing Network for Thermal Mapping of Gold Nanoparticles-Mediated Radiofrequency Ablation.

Sametova A, Kurmashev S, Ashikbayeva Z, Amantayeva A, Blanc W, Atabaev T Biosensors (Basel). 2022; 12(5).

PMID: 35624653 PMC: 9138323. DOI: 10.3390/bios12050352.


References
1.
Haemmerich D, Chachati L, Wright A, Mahvi D, Lee Jr F, Webster J . Hepatic radiofrequency ablation with internally cooled probes: effect of coolant temperature on lesion size. IEEE Trans Biomed Eng. 2003; 50(4):493-500. DOI: 10.1109/TBME.2003.809488. View

2.
Hori T, Nagata K, Hasuike S, Onaga M, Motoda M, Moriuchi A . Risk factors for the local recurrence of hepatocellular carcinoma after a single session of percutaneous radiofrequency ablation. J Gastroenterol. 2003; 38(10):977-81. DOI: 10.1007/s00535-003-1181-0. View

3.
Solomon S, Patriciu A, Bohlman M, Kavoussi L, Stoianovici D . Robotically driven interventions: a method of using CT fluoroscopy without radiation exposure to the physician. Radiology. 2002; 225(1):277-82. PMC: 3107539. DOI: 10.1148/radiol.2251011133. View

4.
Tungjitkusolmun S, Staelin S, Haemmerich D, TSAI J, Webster J, Lee Jr F . Three-Dimensional finite-element analyses for radio-frequency hepatic tumor ablation. IEEE Trans Biomed Eng. 2002; 49(1):3-9. DOI: 10.1109/10.972834. View

5.
Fallone B, Moran P, Podgorsak E . Noninvasive thermometry with a clinical x-ray CT scanner. Med Phys. 1982; 9(5):715-21. DOI: 10.1118/1.595117. View