Background: DNA microarray technology provides a powerful tool for characterizing gene expression on a genome scale. While the technology has been widely used in discovery-based medical and basic biological research, its direct application in clinical practice and regulatory decision-making has been questioned. A few key issues, including the reproducibility, reliability, compatibility and standardization of microarray analysis and results, must be critically addressed before any routine usage of microarrays in clinical laboratory and regulated areas can occur. In this study we investigate some of these issues for the Applied Biosystems Human Genome Survey Microarrays.

Results: We analyzed the gene expression profiles of two samples: brain and universal human reference (UHR), a mixture of RNAs from 10 cancer cell lines, using the Applied Biosystems Human Genome Survey Microarrays. Five technical replicates in three different sites were performed on the same total RNA samples according to manufacturer's standard protocols. Five different methods, quantile, median, scale, VSN and cyclic loess were used to normalize AB microarray data within each site. 1,000 genes spanning a wide dynamic range in gene expression levels were selected for real-time PCR validation. Using the TaqMan assays data set as the reference set, the performance of the five normalization methods was evaluated focusing on the following criteria: (1) Sensitivity and reproducibility in detection of expression; (2) Fold change correlation with real-time PCR data; (3) Sensitivity and specificity in detection of differential expression; (4) Reproducibility of differentially expressed gene lists.

Conclusion: Our results showed a high level of concordance between these normalization methods. This is true, regardless of whether signal, detection, variation, fold change measurements and reproducibility were interrogated. Furthermore, we used TaqMan assays as a reference, to generate TPR and FDR plots for the various normalization methods across the assay range. Little impact is observed on the TP and FP rates in detection of differentially expressed genes. Additionally, little effect was observed by the various normalization methods on the statistical approaches analyzed which indicates a certain robustness of the analysis methods currently in use in the field, particularly when used in conjunction with the Applied Biosystems Gene Expression System.

Citing Articles

protGear: A protein microarray data pre-processing suite.

Mwai K, Kibinge N, Tuju J, Kamuyu G, Kimathi R, Mburu J Comput Struct Biotechnol J. 2021; 19:2518-2525.

PMID: 34025940 PMC: 8114118. DOI: 10.1016/j.csbj.2021.04.044.


Suppressive Effect of Quercetin on Nitric Oxide Production from Nasal Epithelial Cells .

Ebihara N, Takahashi K, Takemura H, Akanuma Y, Asano K, Sunagawa M Evid Based Complement Alternat Med. 2018; 2018:6097625.

PMID: 30069224 PMC: 6057307. DOI: 10.1155/2018/6097625.


Influence of Mechanical Force on Bone Matrix Proteins in Ovariectomised Mice and Osteoblast-like MC3T3-E1 Cells.

Zhang M, Ishikawa S, Inagawa T, Ikemoto H, Guo S, Sunagawa M In Vivo. 2017; 31(1):87-95.

PMID: 28064225 PMC: 5354152. DOI: 10.21873/invivo.11029.


Influence of IL13 on Periostin Secretion by Synoviocytes in Osteoarthritis.

Moue T, Tajika Y, Ishikawa S, Kanada Y, Okumo T, Asano K In Vivo. 2017; 31(1):79-85.

PMID: 28064224 PMC: 5354151. DOI: 10.21873/invivo.11028.


Influence of Periostin on Synoviocytes in Knee Osteoarthritis.

Tajika Y, Moue T, Ishikawa S, Asano K, Okumo T, Takagi H In Vivo. 2017; 31(1):69-77.

PMID: 28064223 PMC: 5354150. DOI: 10.21873/invivo.11027.


References
1.
Wang Y, Barbacioru C, Hyland F, Xiao W, Hunkapiller K, Blake J . Large scale real-time PCR validation on gene expression measurements from two commercial long-oligonucleotide microarrays. BMC Genomics. 2006; 7:59. PMC: 1435885. DOI: 10.1186/1471-2164-7-59. View

2.
Huber W, von Heydebreck A, Sultmann H, Poustka A, Vingron M . Variance stabilization applied to microarray data calibration and to the quantification of differential expression. Bioinformatics. 2002; 18 Suppl 1:S96-104. DOI: 10.1093/bioinformatics/18.suppl_1.s96. View

3.
Patterson T, Lobenhofer E, Fulmer-Smentek S, Collins P, Chu T, Bao W . Performance comparison of one-color and two-color platforms within the MicroArray Quality Control (MAQC) project. Nat Biotechnol. 2006; 24(9):1140-50. DOI: 10.1038/nbt1242. View

4.
Yang Y, Dudoit S, Luu P, Lin D, Peng V, Ngai J . Normalization for cDNA microarray data: a robust composite method addressing single and multiple slide systematic variation. Nucleic Acids Res. 2002; 30(4):e15. PMC: 100354. DOI: 10.1093/nar/30.4.e15. View

5.
Canales R, Luo Y, Willey J, Austermiller B, Barbacioru C, Boysen C . Evaluation of DNA microarray results with quantitative gene expression platforms. Nat Biotechnol. 2006; 24(9):1115-22. DOI: 10.1038/nbt1236. View