» Articles » PMID: 17163276

Relationship Between the Frequency of Blood Pressure Self-measurement and Blood Pressure Reduction with Antihypertensive Therapy : Results of the OLMETEL (OLMEsartan TELemonitoring Blood Pressure) Study

Overview
Date 2006 Dec 14
PMID 17163276
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: This subanalysis of the OLMETEL (OLMEsartan TELemonitoring blood pressure) study in patients with essential hypertension assessed the relationship between the frequency of blood pressure self-measurement (BPSM) and the response to blood pressure (BP)-lowering therapy with olmesartan medoxomil, and the number of BP readings per week necessary to detect a mean systolic or diastolic BP reduction > or =5mm Hg.

Methods: A total of 53 patients with essential hypertension received treatment with olmesartan medoxomil 10, 20 or 40 mg daily for 12 weeks. BPSM was performed for the first 9 weeks using a TensioPhone TP2 device. Patients were instructed to measure BP at least twice daily (morning and evening).

Results: After the first 9 weeks of the 12-week treatment period, the extent of BP reduction correlated with the number of BPSMs. Systolic/diastolic BP reductions in patients with a 100% adherence to at least two BP measurements daily were -16.6/-8.0mm Hg compared with -0.2/-3.3mm Hg in patients with only a 75% adherence to at least one BP measurement daily. Obtaining five home BP readings per week resulted in a sensitivity of 94.8% and a specificity of 90.0% to detect a BP reduction of > or =5mm Hg.

Conclusion: Patients adhering to the instructions for BPSM (at least two measurements daily) had a better response to antihypertensive treatment with olmesartan medoxomil. Whether BPSM per se resulted in an improved adherence to therapy or whether the number of recordings was an indicator of already existing adherence remains to be determined. Obtaining at least five home BP readings per week was identified as the threshold for correctly predicting response to olmesartan medoxomil treatment.

Citing Articles

User engagement with home blood pressure monitoring: a multinational cohort using real-world data collected with a connected device.

Rech J, Postel-Vinay N, Vercamer V, de Villele P, Steichen O J Hypertens. 2024; 43(1):90-97.

PMID: 39315540 PMC: 11608629. DOI: 10.1097/HJH.0000000000003861.


Recommendations for home blood pressure monitoring in Latin American countries: A Latin American Society of Hypertension position paper.

Villar R, Sanchez R, Boggia J, Penaherrera E, Lopez J, Barroso W J Clin Hypertens (Greenwich). 2020; 22(4):544-554.

PMID: 32049425 PMC: 8029829. DOI: 10.1111/jch.13815.


Self-blood pressure monitoring in an urban, ethnically diverse population: a randomized clinical trial utilizing the electronic health record.

Yi S, Tabaei B, Angell S, Rapin A, Buck M, Pagano W Circ Cardiovasc Qual Outcomes. 2015; 8(2):138-45.

PMID: 25737487 PMC: 4366280. DOI: 10.1161/CIRCOUTCOMES.114.000950.


[Possibilities of telemedicine in arterial hypertension].

Sehnert W, Mengden T Med Klin (Munich). 2009; 104(4):314-22.

PMID: 19399391 DOI: 10.1007/s00063-009-1053-3.


Changes in home versus clinic blood pressure with antihypertensive treatments: a meta-analysis.

Ishikawa J, Carroll D, Kuruvilla S, Schwartz J, Pickering T Hypertension. 2008; 52(5):856-64.

PMID: 18809791 PMC: 4593654. DOI: 10.1161/HYPERTENSIONAHA.108.115600.


References
1.
Imai Y, Ohkubo T, Hozawa A, Tsuji I, Matsubara M, Araki T . Usefulness of home blood pressure measurements in assessing the effect of treatment in a single-blind placebo-controlled open trial. J Hypertens. 2001; 19(2):179-85. DOI: 10.1097/00004872-200102000-00003. View

2.
OBrien E, Beevers G, Lip G . ABC of hypertension: Blood pressure measurement. Part IV-automated sphygmomanometry: self blood pressure measurement. BMJ. 2001; 322(7295):1167-70. PMC: 1120288. DOI: 10.1136/bmj.322.7295.1167. View

3.
Mengden T, Chamontin B, Phong Chau N, Luis Palma Gamiz J, Chanudet X . User procedure for self-measurement of blood pressure. First International Consensus Conference on Self Blood Pressure Measurement. Blood Press Monit. 2000; 5(2):111-29. View

4.
Mengden T, Uen S, Baulmann J, Vetter H . Significance of blood pressure self-measurement as compared with office blood pressure measurement and ambulatory 24-hour blood pressure measurement in pharmacological studies. Blood Press Monit. 2003; 8(4):169-72. DOI: 10.1097/00126097-200308000-00008. View

5.
Stumpe K, Ludwig M . Antihypertensive efficacy of olmesartan compared with other antihypertensive drugs. J Hum Hypertens. 2002; 16 Suppl 2:S24-8. DOI: 10.1038/sj.jhh.1001395. View