» Articles » PMID: 17140860

In Vivo Electrical Impedance Measurements During and After Electroporation of Rat Liver

Overview
Publisher Elsevier
Specialty Biochemistry
Date 2006 Dec 5
PMID 17140860
Citations 34
Authors
Affiliations
Soon will be listed here.
Abstract

Electroporation is used for in vivo gene therapy, drug therapy and minimally invasive tissue ablation. Applying electrical pulses across cells can have a variety of outcomes; from no effect to reversible electroporation to irreversible electroporation. Recently, it has been proposed that measuring the passive electrical properties of electroporated tissues could provide real time feedback on the outcome of the treatment. Here we describe the results from the impedance characterization (single dispersion Cole model) for up to 30 min of the electroporation process in in vivo rat livers (n=8). The electroporation sequence consisted of 8 pulses of 100 micros with a period of 100 ms. Half of the animals were subjected to field magnitudes considered to have reversible effects (R group, E=450 V/cm) whereas for the other half irreversible field amplitudes were applied (I group, E=1500 V/cm). As expected, there was an immediate increase of conductivity (R group Deltasigma/sigma(t=0)=9+/-3%; I group Deltasigma/sigma(t=0)=43+/-1%). However, the overall long term pattern of change in conductivity after electroporation is complex and different between reversible and irreversible groups. This suggests the superposition of different phenomena which together affect the electrical properties.

Citing Articles

Pulsed field ablation in medicine: irreversible electroporation and electropermeabilization theory and applications.

Jacobs E, Rubinsky B, Davalos R Radiol Oncol. 2025; 59(1):1-22.

PMID: 40014783 PMC: 11867574. DOI: 10.2478/raon-2025-0011.


Transepithelial Electrical Impedance Increase Following Porous Substrate Electroporation Enables Label-Free Delivery.

Brooks J, Heiman T, Lorenzen S, Mungloo I, Mirfendereski S, Park J Small. 2024; 20(25):e2310221.

PMID: 38396158 PMC: 11186731. DOI: 10.1002/smll.202310221.


Process Analysis and Parameter Selection of Cardiomyocyte Electroporation Based on the Finite Element Method.

Zhang H, Ji X, Zang L, Yan S, Wu X Cardiovasc Eng Technol. 2023; 15(1):22-38.

PMID: 37919538 DOI: 10.1007/s13239-023-00694-y.


Real-Time Temperature Rise Estimation during Irreversible Electroporation Treatment through State-Space Modeling.

Campelo S, Jacobs 4th E, Aycock K, Davalos R Bioengineering (Basel). 2022; 9(10).

PMID: 36290467 PMC: 9598795. DOI: 10.3390/bioengineering9100499.


Single-cell individualized electroporation with real-time impedance monitoring using a microelectrode array chip.

Zhang Z, Zheng T, Zhu R Microsyst Nanoeng. 2021; 6:81.

PMID: 34567691 PMC: 8433324. DOI: 10.1038/s41378-020-00196-0.