» Articles » PMID: 17084056

Direct Quantification in Bioanalytical LC-MS/MS Using Internal Calibration Via Analyte/stable Isotope Ratio

Overview
Specialty Chemistry
Date 2006 Nov 7
PMID 17084056
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

The possibility to rationalize and simplify bioanalysis, without compromising the analytical quality, by omitting the calibration curves was studied. Using mass spectrometry (MS) and a stable isotope labeled internal standard it was possible to get equally good results by calculating the results directly from the analyte/internal standard area ratio and a predetermined response factor as by the traditional way, using a calibration curve run at the same occasion. To be able to use this simplified quantification method, that we call internal calibration, in its most simple form there are some prerequisites that must be considered: (1) The relative response should not be concentration dependent. (2) The relative response should be constant between batches/days. (3) The level of analyte in the internal standard should not be detectable. (4) There should be no influence from naturally occurring isotopes of the analyte on the internal standard peak area. A bioanalytical LC-MS/MS method for a research compound was validated both with and without calibration curves and no significant differences were found regarding precision and accuracy. It was shown that all four prerequisites above were fulfilled. Validation data were very good for the whole concentration range, 0.010-30 micromol/L. Long-term data for QC samples showed excellent precision and accuracy.

Citing Articles

Comparison between a single- and a multi-point calibration method using LC-MS/MS for measurement of 5-fluorouracil in human plasma.

Radovanovic M, Schneider J, Martin J, Norris R, Galettis P J Mass Spectrom Adv Clin Lab. 2024; 33:31-37.

PMID: 39206041 PMC: 11350269. DOI: 10.1016/j.jmsacl.2024.07.003.


Towards clinical adherence monitoring of oral endocrine breast cancer therapies by LC-HRMS-method development, validation, comparison of four sample matrices, and proof of concept.

Jacobs C, Radosa J, Wagmann L, Zimmermann J, Kaya A, Aygun A Anal Bioanal Chem. 2024; 416(12):2969-2981.

PMID: 38488952 PMC: 11045636. DOI: 10.1007/s00216-024-05244-6.


Multitargeted Internal Calibration for the Quantification of Chronic Kidney Disease-Related Endogenous Metabolites Using Liquid Chromatography-Mass Spectrometry.

Visconti G, de Figueiredo M, Strassel O, Boccard J, Vuilleumier N, Jaques D Anal Chem. 2023; 95(36):13546-13554.

PMID: 37655548 PMC: 10500547. DOI: 10.1021/acs.analchem.3c02069.


Speciation and Semiquantification of Nitrogen-Containing Species in Complex Mixtures: Application to Plastic Pyrolysis Oil.

Mase C, Maillard J, Paupy B, Hubert-Roux M, Afonso C, Giusti P ACS Omega. 2022; 7(23):19428-19436.

PMID: 35721918 PMC: 9202011. DOI: 10.1021/acsomega.2c01114.


Development and Validation of a Reliable UHPLC-MS/MS Method for Simultaneous Quantification of Macrocyclic Lactones in Bovine Plasma.

Zeleke G, De Baere S, Suleman S, Devreese M Molecules. 2022; 27(3).

PMID: 35164263 PMC: 8838099. DOI: 10.3390/molecules27030998.