» Articles » PMID: 17061069

Preoperative Evaluation of Hepatic Arterial and Portal Venous Anatomy Using the Time Resolved Echo-shared MR Angiographic Technique in Living Liver Donors

Overview
Journal Eur Radiol
Specialty Radiology
Date 2006 Oct 25
PMID 17061069
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study was to determine whether MR angiography utilizing the time resolved echo-shared angiographic technique (TREAT) can provide an effective assessment of the hepatic artery (HA) and portal vein (PV) in living donor candidates. MR angiography (MRA)was performed in 27 patients (23 men and 4 women; mean age, 31 years) by using TREAT. Two blinded radiologists evaluated HA anatomy, origin of segment IV feeding artery and PV anatomy in consensus. Qualitative evaluations of MRA images were performed using the following criteria: (a) overall image quality, (b) presence of artifacts, and (c) degree of venous contamination of the arterial phase. Using intraoperative findings as a standard of reference, the accuracy for the HA anatomy, origin of segment IV feeding artery and PV anatomy on TREAT-MRA were 93% (25/27), 85% (23/27), and 96% (26/27), respectively. Overall image qualities were as follows: excellent (n=22, 81%), good (n=4, 15%), and fair (n=1, 4%). Significant artifacts or venous contamination of the arterial phase images was not noted in any patient. TREAT-MRA can provide a complete evaluation of HA and PV anatomy during preoperative evaluation of living liver donors. Furthermore, it provides a more detailed anatomy of the HA without venous contamination.

Citing Articles

Non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses: comparison at 1.5 Tesla and 3 Tesla.

Ohno T, Isoda H, Furuta A, Togashi K Acta Radiol Open. 2015; 4(5):2058460115584110.

PMID: 26019890 PMC: 4437907. DOI: 10.1177/2058460115584110.


Non-enhanced T1-weighted liver vessel imaging at 7 Tesla.

Fischer A, Kraff O, Maderwald S, Beiderwellen K, Ladd M, Forsting M PLoS One. 2014; 9(6):e97465.

PMID: 24887206 PMC: 4041637. DOI: 10.1371/journal.pone.0097465.


The diameter of the originating vein determines esophageal and gastric fundic varices in portal hypertension secondary to posthepatitic cirrhosis.

Zhou H, Chen T, Zhang X, Wang L, Zhou L, Dong G Clinics (Sao Paulo). 2012; 67(6):609-14.

PMID: 22760900 PMC: 3370313. DOI: 10.6061/clinics/2012(06)11.


Quality-evaluation scheme for cerebral time-resolved 3D contrast-enhanced MR angiography techniques.

Raoult H, Ferre J, Morandi X, Carsin-Nicol B, Carsin M, Cuggia M AJNR Am J Neuroradiol. 2010; 31(8):1480-7.

PMID: 20448014 PMC: 7966114. DOI: 10.3174/ajnr.A2093.


Multidetector computed tomography for preoperative assessment of hepatic vasculature and prediction of splenic artery steal syndrome in patients with liver cirrhosis before transplantation.

Grieser C, Denecke T, Steffen I, Avgenaki M, Frohling V, Mogl M Eur Radiol. 2009; 20(1):108-17.

PMID: 19662418 DOI: 10.1007/s00330-009-1535-y.

References
1.
Sahani D, DSouza R, Kadavigere R, Hertl M, McGowan J, Saini S . Evaluation of living liver transplant donors: method for precise anatomic definition by using a dedicated contrast-enhanced MR imaging protocol. Radiographics. 2004; 24(4):957-67. DOI: 10.1148/rg.244035186. View

2.
Fink C, Puderbach M, Ley S, Zaporozhan J, Plathow C, Kauczor H . Time-resolved echo-shared parallel MRA of the lung: observer preference study of image quality in comparison with non-echo-shared sequences. Eur Radiol. 2005; 15(10):2070-4. DOI: 10.1007/s00330-005-2831-9. View

3.
Wieben O, Grist T, Hany T, Thornton F, Glaser J, Skuldt D . Time-resolved 3D MR angiography of the abdomen with a real-time system. Magn Reson Med. 2004; 52(4):921-6. DOI: 10.1002/mrm.20230. View

4.
Nael K, Laub G, Finn J . Three-dimensional contrast-enhanced MR angiography of the thoraco-abdominal vessels. Magn Reson Imaging Clin N Am. 2005; 13(2):359-80. DOI: 10.1016/j.mric.2005.03.010. View

5.
Korosec F, Frayne R, Grist T, Mistretta C . Time-resolved contrast-enhanced 3D MR angiography. Magn Reson Med. 1996; 36(3):345-51. DOI: 10.1002/mrm.1910360304. View