» Articles » PMID: 16893918

Angioscopic Differences in Neointimal Coverage and in Persistence of Thrombus Between Sirolimus-eluting Stents and Bare Metal Stents After a 6-month Implantation

Overview
Journal Eur Heart J
Date 2006 Aug 9
PMID 16893918
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Aims: The neointimal coverage and intracoronary thrombi within stented segments at 6 months after implantation between sirolimus-eluting stents (SESs) and bare metal stents (BMSs) were compared by direct visualization using angioscopy.

Methods And Results: Forty-six patients (36 stable angina and 10 acute coronary syndrome) were treated with 33 SESs and 33 BMSs. Immediately after and 6 months after stenting, each of the stented segments, edge body, and overlapping segment were observed by angioscopy and the grade of neointimal coverage over the stents was classified as 0: absent neointima, 1: visible struts through thin neointima, or 2: invisible struts. The existence of thrombi was also evaluated. The average grade of the neointimal coverage at 6 months follow-up was lower in the SES than that in the BMS (edge: 1.4+/-0.7 vs. 1.9+/-0.2, body: 1.0+/-0.5 vs. 1.8+/-0.5, overlapping segment: 0.6+/-0.7 vs. 1.8+/-0.5; P<0.0001, P<0.0001, P=0.0069, respectively). The frequency of persistence of thrombus was significantly higher in the SESs than that in the BMSs (86 vs. 29%, respectively; P=0.031).

Conclusion: The present study suggested a delayed neointimal stent coverage and slower thrombus disappearance process in the SESs in comparison to the BMSs.

Citing Articles

Clinical Importance of the LDL-C/Apolipoprotein B Ratio for Neointimal Formation after Everolimus-Eluting Stent Implantations.

Akutsu N, Hori K, Mizobuchi S, Ogaku A, Koyama Y, Fujito H J Atheroscler Thromb. 2021; 29(4):536-550.

PMID: 33746158 PMC: 9090476. DOI: 10.5551/jat.60954.


The role of intravascular ultrasound in percutaneous coronary intervention of complex coronary lesions.

Malaiapan Y, Leung M, White A Cardiovasc Diagn Ther. 2020; 10(5):1371-1388.

PMID: 33224763 PMC: 7666921. DOI: 10.21037/cdt-20-189.


Restenosis of a Polytetrafluoroethylene-Covered Stent Visualized by Coronary Angioscopy and Optical Coherence Tomography: A Case Report.

Araki M, Hikita H, Sudo Y, Hishikari K, Takahashi A Int J Angiol. 2020; 29(1):58-62.

PMID: 32132819 PMC: 7054065. DOI: 10.1055/s-0039-1685510.


Heme oxygenase-1 (HO-1) alleviates vascular restenosis after balloon injury in a rabbit carotid artery model.

Liu D, Mo X, Zhang H, Wu L, Tan J, Xiao J Int J Clin Exp Pathol. 2020; 11(5):2479-2487.

PMID: 31938360 PMC: 6958238.


Frequency and predictors of thrombus inside the guiding catheter during interventional procedures: an optical coherence tomography study.

Scalone G, Brugaletta S, Garcia-Garcia H, Martin-Yuste V, Azpeitia Y, Otsuki S Int J Cardiovasc Imaging. 2014; 31(2):239-46.

PMID: 25281424 DOI: 10.1007/s10554-014-0544-3.