Fast Electrophoretic Analysis of Individual Mitochondria Using Microchip Capillary Electrophoresis with Laser Induced Fluorescence Detection

Overview
Journal Lab Chip
Specialties Biotechnology
Chemistry
Date 2006 Jul 29
PMID 16874370
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The analysis of mitochondria by capillary electrophoresis usually takes longer than 20 min per replicate which may compromise the quality of the mitochondria due to degradation. In addition, low sample consumption may be beneficial in the analysis of rare or difficult samples. In this report, we demonstrate the ability to analyze individual mitochondrial events in picoliter-volume samples (approximately 80 pL) taken from a bovine liver preparation using microchip capillary electrophoresis with laser-induced fluorescence detection (micro-chip CE-LIF). Using a commercial "double-T" glass microchip, the sample was electrokinetically loaded in the "double-T" intersection and then subjected to electrophoretic separation along the main separation channel. In order to decrease interactions of mitochondria with channel walls during the analysis, poly(vinyl alcohol) was used as a dynamic coating. This procedure eliminates the need for complicated covalent surface modifications within the channels that were previously used in capillary electrophoresis methods. For analysis, mitochondria, isolated from bovine liver tissue, were selectively labelled using 10-nonyl acridine orange (NAO). The results consist of electropherograms where each mitochondrial event is a narrow spike (240 +/- 44 ms). While the spike intensity is representative of its NAO content, its migration time is used to calculate and describe its electrophoretic mobility, which is a property still largely unexplored for intracellular organelles. The five-fold decrease in separation time (4 min for microchip versus 20 min for capillary electrophoresis) makes microchip electrophoretic separations of organelles a faster, sensitive, low-sample volume alternative for the characterization of individual organelle properties and for investigations of subcellular heterogeneity.

Citing Articles

Nanofluidic platform for single mitochondria analysis using fluorescence microscopy.

Zand K, Pham T, Davila Jr A, Wallace D, Burke P Anal Chem. 2013; 85(12):6018-25.

PMID: 23678849 PMC: 4102300. DOI: 10.1021/ac4010088.


Review on recent advances in the analysis of isolated organelles.

Satori C, Kostal V, Arriaga E Anal Chim Acta. 2012; 753:8-18.

PMID: 23107131 PMC: 3484375. DOI: 10.1016/j.aca.2012.09.041.


Simultaneous measurement of concentrations and velocities of submicron species using multicolor imaging and microparticle image velocimetry.

Yang J, Lai Y, Fang W, Hsu M Biomicrofluidics. 2010; 4(1):14109.

PMID: 20644678 PMC: 2905275. DOI: 10.1063/1.3366721.


High-throughput capillary-electrophoresis analysis of the contents of a single mitochondria.

Allen P, Doepker B, Chiu D Anal Chem. 2009; 81(10):3784-91.

PMID: 19344146 PMC: 2682631. DOI: 10.1021/ac900099y.


Recent advances in the analysis of biological particles by capillary electrophoresis.

Kostal V, Arriaga E Electrophoresis. 2008; 29(12):2578-86.

PMID: 18576409 PMC: 3037010. DOI: 10.1002/elps.200700917.