» Articles » PMID: 16849813

Continuous Cardiac Output Monitoring in Humans by Invasive and Noninvasive Peripheral Blood Pressure Waveform Analysis

Overview
Date 2006 Jul 20
PMID 16849813
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

We present an evaluation of a novel technique for continuous (i.e., automatic) monitoring of relative cardiac output (CO) changes by long time interval analysis of a peripheral arterial blood pressure (ABP) waveform in humans. We specifically tested the mathematical analysis technique based on existing invasive and noninvasive hemodynamic data sets. With the former data set, we compared the application of the technique to peripheral ABP waveforms obtained via radial artery catheterization with simultaneous thermodilution CO measurements in 15 intensive care unit patients in which CO was changing because of disease progression and therapy. With the latter data set, we compared the application of the technique to noninvasive peripheral ABP waveforms obtained via a finger-cuff photoplethysmography system with simultaneous Doppler ultrasound CO measurements made by an expert in 10 healthy subjects during pharmacological and postural interventions. We report an overall CO root-mean-squared normalized error of 15.3% with respect to the invasive hemodynamic data set and 15.1% with respect to the noninvasive hemodynamic data set. Moreover, the CO errors from the invasive and noninvasive hemodynamic data sets were only mildly correlated with mean ABP (rho = 0.41, 0.37) and even less correlated with CO (rho = -0.14, -0.17), heart rate (rho = 0.04, 0.19), total peripheral resistance (rho = 0.38, 0.10), CO changes (rho = -0.26, -0.20), and absolute CO changes (rho = 0.03, 0.38). With further development and successful prospective testing, the technique may potentially be employed for continuous hemodynamic monitoring in the acute setting such as critical care and emergency care.

Citing Articles

In silico validation of non-invasive arterial compliance estimation and potential determinants of its variability.

Javorka M, Svec D, Bikia V, Czippelova B, Stergiopulos N, cernanoiva Krohova J Physiol Res. 2025; 73(S3):S771-S780.

PMID: 39808177 PMC: 11827062. DOI: 10.33549/physiolres.935466.


On the similarity between aortic and carotid pressure diastolic decay: a mathematical modelling study.

Bikia V, Rovas G, Anagnostopoulos S, Stergiopulos N Sci Rep. 2023; 13(1):10775.

PMID: 37402771 PMC: 10319712. DOI: 10.1038/s41598-023-37622-y.


Cardiovascular effects of exercise induced dynamic hyperinflation in COPD patients-Dynamically hyperinflated and non-hyperinflated subgroups.

Lukacsovits J, Szollosi G, Varga J PLoS One. 2023; 18(1):e0274585.

PMID: 36662787 PMC: 9858323. DOI: 10.1371/journal.pone.0274585.


Agreement between cardiac output estimation by multi-beat analysis of arterial blood pressure waveforms and continuous thermodilution in post cardiac surgery intensive care unit patients.

Khanna A, Nosow L, Sands L, Saha A, Agashe H, Harris L J Clin Monit Comput. 2022; 37(2):559-565.

PMID: 36269451 PMC: 10068656. DOI: 10.1007/s10877-022-00924-z.


Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference.

Mukkamala R, Kohl B, Mahajan A BMC Anesthesiol. 2021; 21(1):189.

PMID: 34246222 PMC: 8272317. DOI: 10.1186/s12871-021-01415-5.