» Articles » PMID: 16558197

The Role of Limb Torque, Muscle Action and Proprioception During Closed Kinetic Chain Rehabilitation of the Lower Extremity

Overview
Journal J Athl Train
Specialty Orthopedics
Date 1993 Apr 1
PMID 16558197
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

This paper defines the differences between open and closed kinetic chain exercise and explains the role of limb torque, muscle action, and proprioception during rehabilitation of the lower extremity. Closed kinetic chain rehabilitation is shown to decrease shear forces, increase proprioception, and increase muscle group coordination through examples of progressive exercises. The authors conclude that closed kinetic chain rehabilitation is an economical, efficient, and effective means of rehabilitation, with the ultimate goal of enhancing proprioception, thus gaining lower extremity joint stability.

Citing Articles

Effect of Step Load Based on Time under Tension in Hypoxia on the ACL Pre-Operative Rehabilitation and Hormone Levels: A Case Study.

Motowidlo J, Stronska-Garbien K, Bichowska-Paweska M, Kostrzewa M, Zajac A, Ficek K J Clin Med. 2024; 13(10).

PMID: 38792333 PMC: 11122198. DOI: 10.3390/jcm13102792.


Do Patients Achieve "Full Weight-bearing" Immediately Following Application of Circular Frame Fixation of the Lower Limb?.

Craig A, Barron E, Sharma H, Moulder E Strategies Trauma Limb Reconstr. 2024; 19(1):40-44.

PMID: 38752187 PMC: 11091893. DOI: 10.5005/jp-journals-10080-1605.


The effect of modelling parameters in the development and validation of knee joint models on ligament mechanics: A systematic review.

Farshidfar S, Cadman J, Deng D, Appleyard R, Dabirrahmani D PLoS One. 2022; 17(1):e0262684.

PMID: 35085320 PMC: 8794118. DOI: 10.1371/journal.pone.0262684.


Hip Joint Abnormalities During Midstance in Osteoarthritic Patients.

Statescu C, Gavrila B, Deaconu A, Traistaru R, Balseanu T Curr Health Sci J. 2022; 47(3):361-366.

PMID: 35003767 PMC: 8679151. DOI: 10.12865/CHSJ.47.03.05.


Closing the Wearable Gap-Part V: Development of a Pressure-Sensitive Sock Utilizing Soft Sensors.

Luczak T, Burch V R, Smith B, Carruth D, Lamberth J, Chander H Sensors (Basel). 2020; 20(1).

PMID: 31905941 PMC: 6982705. DOI: 10.3390/s20010208.


References
1.
Palmitier R, An K, Scott S, Chao E . Kinetic chain exercise in knee rehabilitation. Sports Med. 1991; 11(6):402-13. DOI: 10.2165/00007256-199111060-00005. View

2.
Keshner E . Controlling stability of a complex movement system. Phys Ther. 1990; 70(12):844-54. DOI: 10.1093/ptj/70.12.844. View

3.
Kamm K, Thelen E, Jensen J . A dynamical systems approach to motor development. Phys Ther. 1990; 70(12):763-75. DOI: 10.1093/ptj/70.12.763. View

4.
Tiberio D . Pathomechanics of structural foot deformities. Phys Ther. 1988; 68(12):1840-9. DOI: 10.1093/ptj/68.12.1840. View

5.
Solomonow M, Baratta R, Zhou B, Shoji H, Bose W, Beck C . The synergistic action of the anterior cruciate ligament and thigh muscles in maintaining joint stability. Am J Sports Med. 1987; 15(3):207-13. DOI: 10.1177/036354658701500302. View