» Articles » PMID: 16547756

Validation of a Computer Analysis to Determine 3-D Rotations and Translations of the Rib Cage in Upright Posture from Three 2-D Digital Images

Overview
Journal Eur Spine J
Specialty Orthopedics
Date 2006 Mar 21
PMID 16547756
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Since thoracic cage posture affects lumbar spine coupling and loads on the spinal tissues and extremities, a scientific analysis of upright posture is needed. Common posture analyzers measure human posture as displacements from a plumb line, while the PosturePrint claims to measure head, rib cage, and pelvic postures as rotations and translations. In this study, it was decided to evaluate the validity of the PosturePrint Internet computer system's analysis of thoracic cage postures. In a university biomechanics laboratory, photographs of a mannequin thoracic cage were obtained in different postures on a stand in front of a digital camera. For each mannequin posture, three photographs were obtained (left lateral, right lateral, and AP). The mannequin thoracic cage was placed in 68 different single and combined postures (requiring 204 photographs) in five degrees of freedom: lateral translation (Tx), lateral flexion (Rz), axial rotation (Ry), flexion-extension (Rx), and anterior-posterior translation (Tz). The PosturePrint system requires 13 reflective markers to be placed on the subject (mannequin) during photography and 16 additional "click-on" markers via computer mouse before a set of three photographs is analyzed by the PosturePrint computer system over the Internet. Errors were the differences between the positioned mannequin and the calculated positions from the computer system. Average absolute value errors were obtained by comparing the exact inputted posture to the PosturePrint computed values. Mean and standard deviation of computational errors for sagittal displacements of the thoracic cage were Rx=0.3+/-0.1 degrees , Tz=1.6+/-0.7 mm, and for frontal view displacements were Ry=1.2+/-1.0 degrees , Rz=0.6+/-0.4 degrees , and Tx=1.5+/-0.6 mm. The PosturePrint system is sufficiently accurate in measuring thoracic cage postures in five degrees of freedom on a mannequin indicating the need for a further study on human subjects.

Citing Articles

Relationship between the bilateral ratios of the thoracic shape and electromyographic activity of the thoracic and lumbar iliocostalis muscles during thoracic lateral translation.

Hirosawa A, Kakizaki F, Komuro N, Homma Y, Omotehara T, Kawata S J Phys Ther Sci. 2023; 35(3):185-192.

PMID: 36866015 PMC: 9974312. DOI: 10.1589/jpts.35.185.


Anterior head translation following cervical fusion-a probable cause of post-surgical pain and impairment: a CBP case report.

Harrison D, Oakley P, Betz J J Phys Ther Sci. 2018; 30(2):271-276.

PMID: 29545692 PMC: 5851361. DOI: 10.1589/jpts.30.271.


Intricate correlation between body posture, personality trait and incidence of body pain: a cross-referential study report.

Guimond S, Massrieh W PLoS One. 2012; 7(5):e37450.

PMID: 22624034 PMC: 3356261. DOI: 10.1371/journal.pone.0037450.


The quality of evidence of psychometric properties of three-dimensional spinal posture-measuring instruments.

Brink Y, Louw Q, Grimmer-Somers K BMC Musculoskelet Disord. 2011; 12:93.

PMID: 21569486 PMC: 3107179. DOI: 10.1186/1471-2474-12-93.


Postural assessment software (PAS/SAPO): Validation and reliabiliy.

Ferreira E, Duarte M, Maldonado E, Burke T, Pasqual Marques A Clinics (Sao Paulo). 2010; 65(7):675-81.

PMID: 20668624 PMC: 2910855. DOI: 10.1590/S1807-59322010000700005.


References
1.
Cholewicki J, Crisco 3rd J, Oxland T, Yamamoto I, Panjabi M . Effects of posture and structure on three-dimensional coupled rotations in the lumbar spine. A biomechanical analysis. Spine (Phila Pa 1976). 1996; 21(21):2421-8. DOI: 10.1097/00007632-199611010-00003. View

2.
Nachemson A, Elfstrom G . Intravital dynamic pressure measurements in lumbar discs. A study of common movements, maneuvers and exercises. Scand J Rehabil Med Suppl. 1970; 1:1-40. View

3.
Harrison D, Cailliet R, HARRISON D, Janik T, Troyanovich S, COLEMAN R . Lumbar coupling during lateral translations of the thoracic cage relative to a fixed pelvis. Clin Biomech (Bristol). 1999; 14(10):704-9. DOI: 10.1016/s0268-0033(99)00030-3. View

4.
Panjabi M, Brand Jr R, White 3rd A . Three-dimensional flexibility and stiffness properties of the human thoracic spine. J Biomech. 1976; 9(4):185-92. DOI: 10.1016/0021-9290(76)90003-8. View

5.
Dvorak J, Panjabi M, Chang D, Theiler R, Grob D . Functional radiographic diagnosis of the lumbar spine. Flexion-extension and lateral bending. Spine (Phila Pa 1976). 1991; 16(5):562-71. PMC: 8009657. DOI: 10.1097/00007632-199105000-00014. View